USCG: fatalities in engine room fire caused by fuel spray ignition
The United States Coast Guard (USCG) has published Safety Alert 4-15 entitled ‘Engine Room Operations: Maintaining Machinery, Knowing Escape Routes, & Conducting Thorough Engineering Watches’.
The safety alert deals with an engine room fire that occurred onboard an older cruise ship while it was at berth. A fuel oil spray under pressure developed from an operating engine’s fuel supply line when a bolted flange parted. The fuel spray ignited when it contacted the engine’s exhaust piping or turbocharger components. The vessel’s fine mist extinguishing system automatically activated and performed as designed extinguishing the primary fire. Fuel pumps and shutoff valves were also secured.
However, the short-duration fire also ignited cable bundles, quickly filling the machinery space with smoke. As a result, one crew member and two technicians were unable to egress and perished in the engine room.
The US Coast Guard has issued this safety alert in order to:
- Reiterate the importance of vessel engineers recognizing and taking action on engine manufacturer technical bulletins and service letters;
- Remind personnel working in machinery spaces to have a personal exit plan no matter where they were working;
- Stress the value of having engineers frequently perform detailed engineering space inspection rounds on engines, systems, and other equipment.
Members will be aware of a number of similar engine room fire incidents, some of which were caused by fuel spray ignition. IMCA Safety Flash 10/14 deals solely with engine room fires.
Safety Event
Published: 2 June 2015
Download: IMCA SF 08/15
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.