Skip to content

LTI: step into open deck hatch causes fall

What happened?

During personnel transfer operations on an offshore renewables crew transfer vessel (CTV), a deckhand stepped backwards into an open hatch and fell, resulting in an injury.

Before the incident the CTV was on standby in the field and the two-man crew were doing maintenance in the starboard hull, with the forward and aft hatches open.  As the handheld VHF signal was obstructed inside the hull, the call for personnel transfer was not heard.  The CTV crew were informed by another CTV and made aware of their call.  The crew finished their maintenance and mobilised for the personnel transfer.  At this point, only the aft hatch was closed.

Just after the personnel transferred aboard, the deckhand, who was receiving the cargo transfer of luggage, stepped backwards into the open hatch with one foot.  In order to try and save himself from falling into the void space, he used his right arm/shoulder on which he landed, resulting in his injury.

The flotel medic boarded the CTV to assess the deckhand; the CTV subsequently went to port to transfer the injured person to hospital for assessment.  He dislocated and fractured his right shoulder resulting in an LTI.  Our member notes that this incident had the potential to have caused permanent injuries or a fatality.

What were the causes?

The direct cause – what went wrong – was that the deckhand stepped backwards and did not see, and thus fell into the open hatch.

  • Underlying causes identified:
    • because of miscommunication between the two crew members, only the aft hatch was closed;
    • the forward hatch was left open when the lifting operations started. There were no barriers around the hatch.  The outside of the hatch was marked yellow and was clearly distinguishable from the deck when closed.  However, there are no proper markings or distinct colour on the inside of the hatch and as a result the hatch is less clearly distinguished when opened
    • VHF radios were used for communication when outside the wheelhouse; when working inside the vessel hull, reception is lost
    • risk assessments for this particular task were not adequate
    • due to the 24-hour operations, ‘pre- and post-sailing checks’ were not being executed at all times. These need to be executed at least prior to sailing away after mooring or maintenance activities
    • it is believed and confirmed that the crew felt pressure to finalise their work, unmoor and mobilise quickly.

What actions were taken?

  • Amend risk assessments to include all relevant preventive measures (including responsibilities for lifting, and deck checks prior to lifting operations and clear means of communication);
  • Provide distinct (colour) marking on the inside of the hatches to make them easily distinguishable when open;
  • During 24hr operations, time for maintenance should be scheduled in;
  • Investigate improvement measures for radio communications when working in the engine room;
  • Reiterate lesson ‘time pressure should be prevented and in case it does occur unexpectedly; this should not lead to rushing or taking short cuts’;
  • Reiterate ‘stop work authority’.

Members may wish to refer to:

Safety Event

Published: 10 January 2020
Download: IMCA SF 02/20

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.