Skip to content

Vessel engine block blown open in and around cylinder

What happened?

A severe engine failure occurred during a major vessel overhaul. The connection rod on cylinder #12 parted from the connecting rod cap and punched a hole in the engine block. The engine had been running for 17 hours, carrying approximately a 20% load.

Parts of the engine block were found spread around the engine room, indicating that the outcome of the event could have been much worse, with potential for personnel injuries and a fire. At the time of the event, the engine room was vacated for lunch. No injuries were sustained, there was no spill of fluids and no fire.

Showing the connection rod on the cylinder blown through the engine block
Debris found spread around the engine room

What went wrong?

Failure to change out and correctly torque up four temporarily installed connection rod bolts. The four bolts were temporarily installed. Preliminary investigation revealed high pressure on work schedule, poor handovers, lack of checklists and incorrect marking of cylinder #12.

What actions were taken? What lessons were learned?

Our member noted the following:

  • Focus on correct and sufficient management of change (MoC) and handovers processes;
  • Use of checklists and marking/signage during work on engines;
  • Limit personnel exposure during start-up of overhauled engines.

Members may wish to review the following incident:

Safety Event

Published: 9 July 2018
Download: IMCA SF 14/18

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.