Slip/trip resulting in lost time injury (LTI)

  • Safety Flash
  • Published on 24 February 2016
  • Generated on 25 November 2026
  • IMCA SF 05/16
  • 3 minute read

A member has reported an incident in which a crewman slipped on deck and fell, resulting in a broken arm.

What happened?

The incident occurred when the chief engineer was returning to the engine room from the bridge via the accommodation. In spite of instructions to stop personnel going on deck during heavy weather, the chief engineer decided to leave the accommodation in the winch housing area to return to the machinery spaces.

Diagram showing path injured crewman took

Outside, there was a small raised deck area, with two steps down to the main deck. The non-skid paint in this area was worn and as the chief engineer stepped out onto this area he slipped and fell forward. His fall and impact caused a fracture of his right upper arm. He received first aid treatment on-board, before being medevac’d ashore for further treatment.

The diagram to the right shows the injured persons path and incident cause. He left the accommodation via Position 1 into the winch housing area.

At Position 2, there was a small raised deck area, with two steps down to the main deck. Here he slipped and fell.

As he fell, he hit the watertight door in Position 3, which was secured open. This impact caused a fracture of his right arm.

Our member notes the following:

  • That morning, the vessel Master had held a training brief on the bridge, advising all personnel of:
    • hazards during heavy weather
    • the need to keep all external doors closed
    • restrictions on using external decks
  • The chief engineer misunderstood and/or chose to ignore the instructions in the briefing and the instructions painted on doors themselves (see image)
Weather tight door
steps crewman slipped on
  • Between the accommodation and the winch housing, the internal door was closed but the external, weathertight door remained open (see image)
  • Between the winch housing into the machinery space stairwell, the external watertight door remained open
  • The raised deck and steps in this area did not have any non-skid painting or coating applied – this was known but had not been previously addressed
  • Despite the proactive briefing held, there was no requirement to conduct rounds and verify that all weathertight openings had been closed and secured
  • No-one exercised the stop work policy.

Our member suggested the following particular lessons:

  • Remain proactive – particularly in unusual operational or working conditions.
  • Go beyond checklists – Don’t be afraid to go above and beyond these requirements to further enhance safety.
  • Safety briefing apply to all personnel – regardless of rank or role.
  • Follow all warning signs – if a door says ‘keep closed at sea’, then keep it closed at sea regardless of previous practice.
  • Particular care should be taken with maintaining watertight integrity and ensuring that all watertight doors remain closed at all times when at sea. Always stop work in unsafe conditions. If you encounter unsafe conditions, then stop the job and ensure all hazards are corrected before allowing anyone else to continue.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.