Tagline incident
- Safety Flash
- Published on 1 July 2003
- Generated on 29 November 2026
- IMCA SF 06/03
- 2 minute read
Jump to:
A Member has reported an incident whereby an injury was sustained by a person during lifting operations on a construction ship.
What happened?
A person was acting as banksman, but also assisted with the handling the load, weighing approximately 1256kg, which was being moved from the starboard aft side of the ship to its moon-pool area. The load had taglines attached to control the load as it was being lifted over ROV system containers.
To help steady the load, the acting banksman wrapped a tagline around a handrail, but his fingers became trapped when the load swung and the tagline became taut. As a result, a part of the person’s left finger was amputated and he sustained superficial rope burns to two other fingers.
The company involved has noted the following as ‘lessons learnt’:
- The banksman was also controlling the tag line. This combination of roles is thought to have resulted in loss of attention.
- The practice of using tag lines needs to take into account of dynamic forces when controlling movement of the load.
- The practice of taking a wrap around the tag line makes it difficult to release in a critical situation.
Recommendations and actions taken
The company’s instructions for lifting equipment and lifting operations were revised shortly after the event. The two key additions were:
- An statement instruction that the banksman is to be solely dedicated to instructing the lifting operation and should not take part in any additional duties.
- A new section ‘Use of Taglines’ describing the consideration of safe positioning, dynamic forces of loads, securing taglines and a warning to never wrap a tagline around any body part for controlling the load.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.