Near-miss: Faulty lifebuoys discovered
- Safety Flash
- Published on 26 October 2012
- Generated on 26 November 2026
- IMCA SF 11/12
- 1 minute read
Jump to:
A Member has reported an incident in which defects were discovered on several lifebuoys aboard a company-owned vessel.
What happened?
During ‘routine’ life-saving appliance checks, it was noted the plug/stopper on one of the lifebuoys was missing. The position where the plug/stopper should have been is shown in the photographs below. These should have been put in place by the manufacturer. In this instance, the lack of the plug had resulted in one lifebuoy being full of water with a resultant loss of buoyancy. A further four lifebuoys were found to have the plugs missing.
The lifebuoy type was EVAL, E.G. Vallianatos S.P.A Greece, Code 559.
Members are recommended to conduct a visual check and, where necessary, a weight check on all lifebuoys onboard for this potential issue. It is recommended to amend onboard planned maintenance schedules such that that they include quality control checks and inspection of lifebuoys.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.