Windfarm Support Vessel Njord Forseti hit wind turbine tower – Jersey Maritime Administration

  • Safety Flash
  • Published on 23 October 2020
  • Generated on 25 November 2026
  • IMCA SF 30/20
  • 3 minute read

The Jersey Maritime Administration has published a report into its investigation of the causes of an allision between a windfarm support vessel and a windfarm tower in the Southern North Sea on 23 April 2020.

The report can be found on the web here.

What happened?

Shortly after 1800 local time, the vessel was released from duties on a windfarm and at 1811 departed for the return passage to port.

Aboard the vessel were three crew members, and one windfarm technician who was being transferred ashore.

Sea conditions were calm with light winds and low swell. Weather was fair with good visibility.

Whilst transiting between windfarms at approximately 20 knots, Njord Forseti hit a turbine tower.

The impact resulted in serious damage to the vessel. Two crew members were evacuated by air to hospital, and the third was required to have a subsequent medical examination. Immediate assistance was provided by a nearby offshore construction vessel. 

The Njord Forseti returned to port under her own power with temporary crew members provided by a sister vessel.

Whilst transiting between windfarms at approximately 20 knots, Njord Forseti hit a turbine tower

Findings

The Jersey Maritime Administration report drew the following conclusions:

  • For an indeterminate period between departure from the windfarm until the incident occurred, the vessel crew were not keeping a proper look out as required by Rule 5 of the International Regulations for Preventing Collisions at Sea (COLREGS).

  • The primary reason why a proper lookout was not being kept was because the Master was distracted from his primary role.

  • It is possible that the Master was distracted from his primary role as he may have been adjusting of settings on the VHF radio which is mounted immediately to starboard of his seat. However, this has not been positively determined and distractions caused by other means cannot be ruled out.

  • At the time of the incident the vessel was not following the established passage plan from the windfarm to port, but was undertaking an alternative route. Whilst this route was safe, ineffective monitoring of the vessels track, position and proximity to navigational hazards contributed to the incident.

Recommendations

The Jersey Maritime Administration report made the following recommendations:

  • There should be renewed emphasis on the importance of compliance with COLREGS, and particularly Rule 5.

  • Identify tasks, equipment and functions that may give rise to possible distractions for the person having the conduct of a vessel whilst underway, and implement measures to ensure that the safe conduct of the vessel is not impaired by these or other factors.

  • Review the methods by which Masters monitor the safe progress of a vessel’s passage and make changes as necessary, including where necessary, additional training.

  • Under the Workboat Code, other than the need for at least one person to ensure the safe conduct of the vessel whilst underway, there is no specified minimum number of (deck) watchkeepers required. Operations should be assessed and policies updated where necessary to ensure that the wheelhouse is always sufficiently and appropriately manned. Where appropriate, specific guidance should be provided to the Master in exercising his / her judgement in setting the wheelhouse manning level during the course of a voyage (IMCA emphasis).

  • Develop principles and techniques of crew resource management (CRM) to ensure that whilst underway the conduct of the vessel is carried out in the most effective and efficient means possible.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.