Product caution notice relating to commercial diving equipment: gas conditioner charges
- Safety Flash
- Published on 27 February 2019
- Generated on 15 November 2026
- IMCA SF 03/19
- 2 minute read
Jump to:
JFD has issued a Product Caution Notice to inform you of a potential safety issue with commercial diving equipment manufactured/supplied by JFD.
What happened?
JFD is aware of a potential safety issue and is advising customers and end users that all stock of this item requires inspection before use.
This product caution notice applies to the following equipment supplied by JFD:
- B1562A DISPOSABLE CARTRIDGE SET, GASMIZER
- B1591A DISPOSABLE CARTRIDGE SET, GASPURE
- B1563 DISPOSABLE CARTRIDGE SET, AIR FILTER SYS, 2 SETS BO
- B1592A GASPURE CO CATALYST CARTRIDGE
What went wrong?
A manufacturing defect has been identified with a batch of the components used for the bottom nozzle of the cartridge.
Some of these nozzles are misshapen and will not correctly seal the disposable cartridge into the stainless-steel pressure housing.
This will lead to a certain amount of the non-treated gas bypassing the cartridge and not being subject to the treatment provided by the chemicals within the cartridge.
Recommendations
JFD recommends that all Disposable Cartridges are subjected to the following inspection before use:
Pre-use inspection:
- Visually inspect the nozzle on each cartridge to check for damage similar to that shown in Figure 1.
- Grip the nozzle between the thumb and forefinger and rotate the cartridge to check for flat spots, out of roundness and any other damage missed during the visual inspection.
- Using suitable digital callipers, check the OD of the nozzle is 20.7mm/20.6mm as shown in Figure 2. A number of different diameter measurements should be taken to confirm the roundness of the nozzle.
Possible indication of damage during use (B1562A only) is a higher than expected CO2 level in the post scrubber gas sample immediately after cartridge change. This may indicate gas bypassing the cartridge.
Figure 2: Dimensions of nozzle
Damaged Cartridge
Any unit which is found or suspected to be defective should not be used and should be returned to JFD for replacement.
Any item of which the user is unsure of its suitability can be returned to JFD for assessment.
If you have any queries or need any additional information, please contact JFD at [email protected].
Members may wish to refer to:
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.