Positive: Vessel improvements made following a man overboard incident

  • Safety Flash
  • Published on 19 January 2021
  • Generated on 13 October 2026
  • IMCA SF 03/21
  • 2 minute read

While investigating a man overboard incident, a Member conducted a thorough review to identify how crew transfer over vessel bow areas could be improved

What happened?

Following a non-fatal man overboard incident involving a member of a mooring gang falling off a tug, as part of the incident investigation, a thorough review was conducted to identify how crew transfer over vessel bow areas could be improved.

Image10

Bow fendering enhancements

Image11

Photo showing obstruction free bow

Image12

Modified bow

Immediately post-incident, removable hand rails were installed in the bow area, provided with enhanced grip points for transferring personnel.  It was identified that still further improvement could be made in this area.  As well as the physical enhancements, customised HSE refresher training was provided to the personnel on:

  • the importance of ‘three-point contact’ whilst transferring

  • the use of personal flotation devices, and

  • the buddy system of giving your fellow team members behind you the required support and help during transfer.

The tug involved went to dry dock shortly after, and it was decided to remodel the bow area to provide an obstruction free bow embarkation/disembarkation platform at bulwark top height, with vastly increased landing area to the original vessel design with additional stringers and stanchions added. Bow fendering enhancements were also made during this modification with heavy duty 500mm ‘D’ fender installed around the radius of the new platform for enhanced asset protection.

Since the photos above were taken the landing area and the step-up platform have also been coated with yellow/black hazard marking stripes.

Positive Findings

  • The modifications completed have provided far greater safety and security for crew during personnel transfer operations over the bow.

  • There was excellent cooperation between the technical, HSE and marine departments in working to reduce the risk.

  • The team did not settle for average and explored every possibility to increase the safety for the mooring gangs.

Our Member will be suitably modifying all their similar tugs in the same fashion as they dock over the coming 12-18 months.

Latest Safety Flashes:

Hydraulic oil leak detected below moonpool

A hydraulic oil leak was identified below the moonpool after the worktable doors were opened.

Read more
Dropped scaffold board (kickplate) – SIF near miss

A scaffolding kickboard was accidentally dropped falling from a height of 6.5 metres to the main deck.

Read more
H₂S detected on deck

During vessel transit back to port, Hydrogen Sulphide (H₂S) was detected in the open space on the main deck.

Read more
Restoration and verification after maintenance

A missing flooring panel was identified beneath a 415V bow thruster electrical motor cabinet.

Read more
Vessel contact during materiel transfer in adverse weather

One vessel lost heading and position control because of the strong winds and swell, pushing it toward another.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.