Fractured finger while handling metal plates

  • Safety Flash
  • Published on 28 February 2022
  • Generated on 17 November 2026
  • IMCA SF 05/22
  • 2 minute read

A crew member suffered a pinch injury to his right hand baby finger, resulting in a distal fracture.

What happened?

While working on deck, a crew member suffered a pinch injury to his right hand baby finger, resulting in a distal fracture to the tip of the finger and a significant laceration requiring sutures to the finger above the nail bed.

What went wrong?

Heavy weather had caused damage to welded plates on deck.  While manually handling the plate back into position with another crew member, the injured person suffered a pinch injury to his finger which was trapped between the plate and frame. Following a medical review, the vessel headed into port to permit further diagnosis at hospital.  An X-ray showed a distal fracture to the tip of the finger and the wound required stitches.

Photo of welded plates on deck

What was the cause?

  • The design of the plate did not allow for safe manual handling.
  • The installation of the plate had a permanent risk of finger entrapment.
  • The risk assessments and toolbox talk used were generic in content and not task specific.
  • The JSA used was for hot work only and did not include manual handling at all.

Lessons learned

  • Safety by design: the plate was subsequently modified to have a pair of temporary handles to keep fingers away from the pinch points.
  • Magnetic lifting handles sourced as a long term solution.
  • Take care with generic risk assessments – ensure they are either modified to suit the task, or use a dynamic risk assessment or toolbox talk specifically for a full and thorough review of the task.
  • If the task is slow, uncomfortable or inconvenient, can we use the toolbox talk or JSA to better define and understand these areas of risk? Can we remove the risk or reduce its likelihood or severity?

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.