Kirby Morgan one-way valves (follow-up to IMCA Safety Flash 09/05 item 1)

  • Safety Flash
  • Published on 21 June 2006
  • Generated on 11 October 2026
  • IMCA SF 07/06
  • 1 minute read

Further to Kirby Morgan Safety Notice #1 of 2005, Kirby Morgan Dive Systems Inc. has issued the attached Product Bulletin #2 of 2006,reporting that, following recall of one-way valves p/n 555-195 (see IMCA safety flash 09/05 (Malfunction of Kirby Morgan B17 side block non-return valve) and Kirby Morgan safety notice #1 of 2005), these valves have all been re-tested and re-certified; and have been proven to be fully functional and fit for their intended purpose.

These valves now have two date stamps, as shown in the picture. The stamp on the cylindrical valve body is the original manufactured date. The date on the hexagonal valve seat is the date of the re-test.

Kirby Morgan Valve

Latest Safety Flashes:

Hydraulic oil leak detected below moonpool

A hydraulic oil leak was identified below the moonpool after the worktable doors were opened.

Read more
Dropped scaffold board (kickplate) – SIF near miss

A scaffolding kickboard was accidentally dropped falling from a height of 6.5 metres to the main deck.

Read more
H₂S detected on deck

During vessel transit back to port, Hydrogen Sulphide (H₂S) was detected in the open space on the main deck.

Read more
Restoration and verification after maintenance

A missing flooring panel was identified beneath a 415V bow thruster electrical motor cabinet.

Read more
Vessel contact during materiel transfer in adverse weather

One vessel lost heading and position control because of the strong winds and swell, pushing it toward another.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.