Loss of a vessel
- Safety Flash
- Published on 1 September 2002
- Generated on 20 September 2026
- IMCA SF 09/02
- 3 minute read
Jump to:
We have received the following information regarding loss of a survey vessel.
There were no injuries amongst the 29 crew members, who were safely carried to shore.
Circumstances
The company involved was contracted to conduct a seabed survey for a proposed pipeline and the vessel involved was tasked with carrying out the work scope.
On arrival at location the survey operations commenced by deployment of an acoustic transceiver pole through the vessel’s hull via a gland, support stool and gate valve. The system is located in the ship’s engine room.
The transceiver pole weighing approximately 500 kg and 5m in length was lowered by a chain block assembly. At some point during the lowering and for reasons unknown, the pole fell freely some four to five metres. The retaining collar and supporting steelwork were destroyed by the inertial energy of the pole thus the pole was lost to sea.
Thereafter there was ingress of water into the engine room from the open gland. The control wheel to the gate valve, which was situated at the base of the support stool was almost immediately submerged preventing access by staff to close it.
The watertight doors to the port and starboard shaft tunnels were closed and the engine room evacuated. Distress calls were initiated, the company’s office advised and a nearby support vessel closed in to render assistance and to receive all non-essential personnel off the vessel. Assistance was also obtained from a nearby coalition force vessel with helicopter support. Once it was quickly established there was no risk to personnel efforts were focussed on saving the ship.
Regrettably only one of three pumps landed onboard the vessel was operable. Given this situation all remaining personnel were removed, thereafter the vessel remained afloat a further three hours, sinking in 3,000 metres of water.
Both the Master and his team, supported by the various vessels, agencies and the company emergency response team, managed the whole nine hour incident in a controlled manner. The entire crew of 29 were transferred by vessel’s rescue craft without injuries or incident of any kind.
Follow Up
The company involved, together with regulatory agencies, is continuing to investigate the incident. These investigations have, and will continue to be, focused on the cause and contingency systems.
However, given the recent vessel losses and incidents within the both the deep seismic and high-resolution seismic industry the company involved believes the view that “it cannot happen to us” must be challenged. The company involved has advised others to review their processes and the effects of their actions. It is with this focus in mind and the best interests of the industry that the company involved has indicated that it will make available the regulatory findings and make recommendations to the classification society which, if implemented, should avoid such a repetition to other vessels.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.