LTI: Leg injury caused during HP water jetting

  • Safety Flash
  • Published on 3 May 2017
  • Generated on 8 September 2026
  • IMCA SF 09/17
  • 2 minute read
  • During diving operations to clean a riser with a high pressure (HP) water jet type Cavitek, a diver cut his leg (thigh) with the water jet.

What happened?

The incident occurred whilst the diver was not properly secured during the cleaning operation.

The diver should always be comfortably and securely positioned during HP water jetting operations. It is especially important to ensure that this is so during mid-water work, otherwise there is a greater likelihood that the diver may lose control of the trajectory of the jet stream during jetting operations. 

The likelihood of such an event will also be increased if the retro jet and forward jet on the gun is strongly unbalanced.

Cavitek type high pressure water jet

Cavitek type high pressure water jet

Our member notes that there was an incorrect calculation of the HP hose length needed for this job. The minimum length of hose required per jetting gun unit is normally considered to be 1.5 times the maximum anticipated working depth. The length of the hose should not impact upon the comfort and security of the diver during HP water jetting operations.

The length of the waterjet lance may not have been appropriate (too short). The inherent potential for accidental self-injury during use of high pressure jetting guns increases as the length of lance (barrel) decreases.

IMCA Code of practice for the use of high pressure jetting equipment by divers states that:

“Hoses should be tied off at convenient locations to assist in minimising movement due to pressure supply changes or tidal/current movement.

Hoses should never be tied off to any part of any diving equipment.”

Key lessons learned

  • Before water jetting operations:

    • Ensure proper and dedicated tool box talks are held.

    • Ensure there us a full assessment of risks and needs at the work area.

    • Check the required length of hose.

  • When cleaning vertical parts of structures in mid-water divers should be rigged to be stable and comfortable for jetting operations.

  • Check that the gun is appropriately designed, properly balanced, well-maintained and fit for purpose.

  • Ensure the diver holds the gun with two (2) hands.

  • Stop/release the trigger before each movement.

  • Ensure regular communication from the diver to the dive supervisor about the situation at depth.

Remind the dive team of the importance of good communications and consistent observance of safe working practices.

Latest Safety Flashes:

GPS jamming and spoofing – good practice example

A Member’s vessel in the Red Sea encountered GPS jamming.

Read more
LTI – Shoulder strain when crew member was descending the stairs

A crew member sustained an injury to their shoulder as they were descending a flight of stairs into an ROV hangar.

Read more
Emergency escape hatch found blocked

Emergency escape hatch to the deck could not be opened.

Read more
Crew member sustained hand injury during lifting operations

A crew member sustained a hand injury during a lifting operation involving a main engine cylinder head.

Read more
NOPSEMA: Lifting operations dangerous occurrences and injuries

NOPSEMA has published a safety bulletin relating to lifting operations in the offshore industry.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.