Trapped finger during mooring operations

  • Safety Flash
  • Published on 30 April 2024
  • Generated on 17 May 2026
  • IMCA SF 09/24
  • 2 minute read

A deckhand injured the fingers on his right hand during mooring operations.

What happened?

A deckhand injured the fingers on his right hand during mooring operations. The incident occurred when a vessel was headed to the pontoon to moor alongside her regular berth. As the vessels’ aft port quarter came alongside the pontoon, the deckhand used the boat hook to pick up the ‘in-situ’ mooring line and began the process of feeding the spliced eye through the fairlead. He then began placing the line over the bitts, this is where the deckhands’ fingers on his right hand became trapped. One finger was seriously injured, and minor injuries to the other two.

Trapped finger during mooring operations

This photo may show graphic content.

What went wrong?

  • The immediate causes were:
    • There was insufficient slack in the mooring line to allow the task to be completed safely.
    • The vessel was moving forward as the task was performed.
    • Whilst there was a risk assessment in place for the task, including gloves, it did not specifically include impact gloves, nor had an assessment been made on whether they were required.
    • The newest and least experienced deckhand was completing the task and there was only a mooring line with a splice eye available.
  • The root cause was seen to be a lack of risk perception.

This incident could have had a high potential for a more serious injury.

Corrective actions and lessons learned:

  • The investigation highlighted several corrective actions to be put in place:
    • More thorough Toolbox Talks for mooring arrangements.
    • Review risk assessment for mooring operations.
    • Obtain and try out certain high impact gloves.
    • Review of training and follow up supervision and review of design of vessel mooring arrangements.
  • Ensure that sufficient slack is allowed when handling mooring lines.
  • Where practicable, vessel should be stopped before mooring lines are placed over bitts, bollards, or cleats.
  • Ensure new personnel (persons who are not yet experienced on a particular vessel) are appropriately familiarised.
  • The use of single ended lines or the use of small rope extensions on the spliced eyes would avoid exposing fingers and hands to risk.

Members may wish to refer to:

Latest Safety Flashes:

Worker suffered crush injury while handling unstable steel plates

Steel plates suddenly toppled over to the side trapping a worker's left hand and wrist between a frame and an emergency stop pedestal.

Read more
High Potential Near Miss: Dropped object due to contact with crane sheave

A Dynamic Positioning (DP) beacon came into contact with sheave protection bars, resulting in the beacon and its holder assembly detaching and falling to the deck below.

Read more
Machinery damaged through improper maintenance technique

During an audit on an offshore vessel it was observed that the fuel oil purifier failed to self-discharge.

Read more
Shifting cargo and deck spill during heavy weather

A sodium chloride brine storage tank shifted approximately 0.5m during heavy weather conditions.

Read more
MSF: Fast Rescue craft (FRC) washed overboard and lost at sea

The Marine Safety Forum (MSF) has published Safety Alert 26-03 relating to the loss of a Fast Rescue Craft (FRC).

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.