Diver experienced an air flow restriction

  • Safety Flash
  • Published on 21 April 2022
  • Generated on 17 November 2026
  • IMCA SF 10/22
  • 3 minute read

At the beginning of an air dive at 23msw, a diver experienced an air flow restriction.

What happened?

The system used was considered as a Mobile Surface Supplied System, the daughter craft was moored to the platform, the mother vessel was ready in the vicinity at about 200m.

Predive checks were performed and recorded on deck before starting the dive. When at depth, 23msw, diver 1 reported the air was getting tight and informed his supervisor he was going onto bailout. The Diving Supervisor first increased the pressure on primary supply, then switched from primary to secondary supply, and instructed the diver to close his bail out. The diver did so and confirmed he was on main gas. The Diving Supervisor aborted the dive.  The diver returned back to surface and was safely recovered on deck.  The daughter craft went back to the mother vessel for investigation of the equipment by the dive technician.

The event lead to the abort of the dive, no-one was injured.  Operations were interrupted for investigation and the event was recorded as a near miss.

What went right?

  • All equipment maintenance was in-date, and IMCA audits were done at the mobilization.
  • Equipment familiarization had been performed at the start of the project.
  • The dive system was maintained daily throughout the project.
  • The dive system has been used daily for a month with no incident, this was the 103rd dive of the project.
  • On investigation, the following was noted:
    • Diver 1’s helmet was completely checked and tested and was found in normal working condition.
    • Diver 1’s umbilical was checked and found free of twist, bent and deformation.

What went wrong?

  • Diver 1’s panel was tested at 15 bar with all needle valves fully open. It was noticed that Diver 1’s primary needle valve was hard to open fully.
    • Direct cause: The needle valve was not opening as it should, restricting the air flow.
    • Root cause: Premature fatigue of the equipment, could be due to an overtightening of the valve over time.

Actions taken

  • The needle valve was replaced with a new one.
  • Updated the pre-dive checklist to include an item to confirm that the status of the valve is open fully with a ¼ turn back.
  • Amended onboard procedures – to not overtighten the valves either when opening or closing.
  • Supervisors and divers to report any anomaly in the equipment, even when they seem minor.
  • A debriefing was done with the whole team covering the emergency procedure for loss of main air.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.