Incident 1 – finger severed

A crewman was in the process of unlocking a blow-out preventer (BOP) ram. The employee decided to place his finger into a sight opening slot to make sure the locking screw was completely out. Another member of the crew engaged the ram control valve whilst the first person’s finger was still in the slot resulting in his left index finger being severed.

Causes:

  • There was no isolation, lock out or tag out to prevent this from happening.
  • There was no apparent understanding or communication between the injured person and the operator of the ram control valve.

Corrective action: A temporary guard was manufactured and placed over the BOP ram shaft bonnet to prevent crew placing their fingers into the shaft compartment.

See the IADC safety flash here.

Incident 2 – Finger pinch injury leads to LTI

A crewman was requested to assist on a cargo handling operation from the main deck. The task was to connect the crane hook to the slings of a pup joint bundle. The bundle was to be sent over to a platform with the use of the crane. When the crewman, who was working on his own, signalled to the crane operator to pick up the load, movement of the rig allowed the bundle of pup joints to sway in his direction and he pinched his right hand between two joints, fracturing two fingers in the process.

Causes:

  • Standing too close to the load as it was hoisting
  • Using a team member who was not originally part of the task
  • Failure to use taglines and/or push poles to control the load
  • Failure to follow the correct rigging and lifting techniques by using only one man for the job
  • Failing to think about the risks involved
  • Not utilising the stop work authority

Corrective actions:

  • No job is so important that we cannot take the time to do it safely
  • Job hazard analysis for the task should have been completed and discussed with all crew involved
  • Crew should stand clear of load while hoisted and using proper taglines and handling tools
  • Supervisors need to understand and manage situational changes
  • Use safety interventions such as Step back 5 x 5 and the stop work authority when required
  • Time to be taken to have correct amount of people to do the job at all times

See the safety alert here.

Members should be aware that IMCA publishes a series of pocket safety prompt cards, including Watch your hands.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.