Exploding light and smoke marker
- Safety Flash
- Published on 1 November 2001
- Generated on 26 November 2026
- IMCA SF 13/01
- 2 minute read
Jump to:
A Member has reported that two Ikaros man-overboard light and smoke markers, manufactured by Hansson Pyrotech, were returned from one of its ships to its shore-based workshops.
What happened?
The units had been stored on a pallet and a storeman was in the process of moving each unit to another location.
As he moved one of the units, it exploded with a loud bang, resulting in parts of the assembly shooting across the room. Fortunately he was not struck by flying fragments nor was he otherwise injured. The smoke itself did not activate in the explosion, but instead the smoke powder was widely dispersed.
The company’s investigations identified that:
- The storeman had not released the pin or moved any trigger mechanisms to activate the unit.
- The safety pin was still in the unit when the parts were recovered.
- The unit had been subjected to pressure build up from the way it had been torn apart rather than by normal activation of the smoke system.
- The unit was still within its safety bracket when it was moved.
The unit was subsequently returned to suppliers for further examination and, although it is not conclusive, they have stated that the unit may not have had the safety pin fitted correctly, thereby allowing the detonator to fire but preventing the correct release of the smoke capsule. The resultant pressure build up caused the unit to explode rather than flare off the smoke.
Conclusion
As this event followed within just a week of IMCA releasing a safety flash on another incident involving smoke flares which did cause serious injury (Safety Flash 12/01 – Serious incident while checking man-overboard and buoy smoke marker), the company was concerned that there was a fault with these devices which could have caused further injury.
Dialogue with the manufacturers and UK marine authorities is ongoing to further investigate such events. The two manufacturers (the previous notice concerned a Pains Wessex unit) are concerned that there could be a fault with their units, but their responses have been guarded.
Personnel should be made aware that at least two unexplained incidents have occurred and to avoid handling such devices whenever possible for inspection purposes. If they are to be transported, it should be ensured that the manufacturers’ instructions are followed exactly and that the safety pin is correctly fitted.
Related safety flashes
-
IMCA SF 12/01
2 October 2001
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.