MAIB: Anchor failures
- Safety Flash
- Published on 20 May 2021
- Generated on 9 October 2026
- IMCA SF 14/21
- 3 minute read
Jump to:
The UK Marine Accident Investigation Branch (MAIB) has published Safety Bulletin 1/2021 relating to anchor failures.
What happened?
The COVID-19 pandemic has seen many cruise vessels anchored off the UK’s south coast. During this period there were several anchor losses associated with the inclement weather over the autumn and winter and the use of the anchoring equipment beyond its intended design parameters.
The MAIB has been made aware of several marine incidents since October 2020 where cruise ship anchors or anchor cables have failed, often while trying to ride out named winter storms. One cruise ship lost both its anchors within a week.
The MAIB have identified a trend in the nature of anchoring equipment failures and have released this safety bulletin to the cruise industry to mitigate against further losses both in the short term and when the vessels return to normal operations.
Though this bulletin is about cruise ships, the principles of safe management and use of anchors are relevant to all IMCA Members' operating vessels.
MAIB recommendations
- Operational limits for anchoring must be sufficiently cautious to ensure weighing anchor is not left too late, risking overloading anchor equipment. If strong winds are forecast, proactive action should be taken to seek a more sheltered anchorage in good time or proceed to sea and ride out the weather.
- Do not wait until the anchor drags or until most of the anchor cable has been paid out before weighing anchor.
- Steps should be taken to minimise the wear on the anchoring equipment as far as possible. When the opportunity presents itself, the anchor in use should be rotated and the scope of cable varied on a regular basis to minimise single point loading. An appropriately experienced crew member should also carry out regular checks on the windlass brake condition and areas where the cable is in contact with the ship.
- While at anchor for significant periods, ensure all watchkeepers are confident in the actions to be take in the event of dragging or losing an anchor and there is a contingency plan ready for implementation in the event of having to proceed to sea or re-anchor. Also, watchkeepers and senior officers must be aware of the reporting requirements to the coastal state in the event of losing an anchor so that mitigation measures can be put in place if required.
- Anchoring equipment should be assessed before returning back into normal service if it has seen greater use at extraordinary times.
Related Safety Flashes
-
IMCA SF 03/21
19 January 2021
-
IMCA SF 26/19
12 November 2019
-
-
IMCA SF 01/09
16 January 2009
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.