MAIB: Who is in control?

  • Safety Flash
  • Published on 12 June 2023
  • Generated on 13 October 2026
  • IMCA SF 14/23
  • 3 minute read

Control was lost of a vessel and it almost ran aground.

What happened?

Fortunately, the crew were able to regain control before the vessel (a ferry) grounded, and the voyage continued safely.

The vessel was fitted with a Voith Schneider Propeller. The system could be controlled from joysticks on one of three consoles on the port, starboard or centre of the bridge. Control was exchanged by pressing a command button at one of the consoles and confirmed by pressing the button a second time. An audible tone would indicate when there was misalignment between the joysticks of the two consoles and the transfer would not take place.

The Master was using the starboard console to manoeuvre the ferry out of port on the morning of the incident. The helmsman pressed the command button on the centre console to request control as normal and the audible tone sounded. The master, believing control had been passed, set the starboard console’s joystick to the zero position. However, the audible tone continued. This was confusing. Neither the Master nor helmsman knew who was in control. The ferry slowed and swung to port. The bridge team attempted to take control at each console station and in doing so the control passed backwards and forwards many times.

The vessel was fitted with a Voith Schneider Propeller. The  system could be controlled from joysticks on one of three  consoles on the port, starboard or centre of the bridge. Control  was exchanged by pressing a command button at one of the  consoles and confirmed by pressing the button a second time.  An audible tone would indicate when there was misalignment  between the joysticks of the two consoles and the transfer  would not take place.

The audible tone stopped shortly afterwards, indicating that the transfer process had timed out.

The bridge team then zeroed all the joysticks and successfully transferred control to the centre console after pressing the command button at that station twice.

The ferry was able to pull back from the beach and resume its passage.

What went wrong?

  • The angle of the control display panels made it difficult to see which console was in control – previous modifications to the position of the display panels had inadvertently made it harder to see them.
      
  • Confusion arose and neither the Master nor helmsman knew who was in control. 

Actions

  • Equipment:

    • With dual or other complex control systems, ensure there is a robust system for identifying which console has control at any time.

    • Control indications should be unambiguous and any modifications need to be carefully considered so that the fixing of one problem does not create another.

  • Training and competence:

    • When the equipment did not operate as expected it took time for the bridge team to regain control. This circumstance was in the manual – greater familiarity with procedure may have quickened the bridge team’s response to the loss of control.

Latest Safety Flashes:

Hydraulic oil leak detected below moonpool

A hydraulic oil leak was identified below the moonpool after the worktable doors were opened.

Read more
Dropped scaffold board (kickplate) – SIF near miss

A scaffolding kickboard was accidentally dropped falling from a height of 6.5 metres to the main deck.

Read more
H₂S detected on deck

During vessel transit back to port, Hydrogen Sulphide (H₂S) was detected in the open space on the main deck.

Read more
Restoration and verification after maintenance

A missing flooring panel was identified beneath a 415V bow thruster electrical motor cabinet.

Read more
Vessel contact during materiel transfer in adverse weather

One vessel lost heading and position control because of the strong winds and swell, pushing it toward another.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.