Uncontrolled ascent of spool and diver during a lifting bag operation

  • Safety Flash
  • Published on 9 October 2008
  • Generated on 11 August 2026
  • IMCA SF 15/08
  • 2 minute read

A Member has reported the uncontrolled ascent of a spool piece and diver during a lifting bag operation.

What happened?

In low visibility conditions, whilst preparing a pipe spool for re-positioning on the seabed using air lift bags, the spool became positively buoyant and started ascending to surface in an uncontrolled manner.

The diver working at one end of the spool became entangled with the air lift bag inverter line, resulting in him ascending with the spool from 55msw (seabed) to 36msw.

During this ascent, the diver’s umbilical was damaged, causing restricted gas flow and severing of his communication and video cables. He reverted to his emergency gas supply and managed to cut the line that had fouled on his bail out bottle, enabling him to immediately return to the seabed.

A second diver, also working on the spool (but still on the seabed), followed the umbilical of the ascending diver and subsequently accompanied him back to the bell (at 47msw). The bell was recovered for the immediate examination of the diver and it was confirmed that no injuries were sustained. The spool was later re-positioned without incident.

Our Member’s investigation revealed the following:

The Member identified that the lift bags had been inflated without appropriate ‘hold back rigging’ in place and that there had been a failure to follow company procedures and guidance detailed in Guidance on open parachute type underwater air lift bags.

The Member also noted that the dive plan steps had not been as clear as they should have been and that ‘installing lift bags complete with hold backs’ had been detailed as a single step without a check to confirm that the hold back rigging installation was done prior to inflating the air lift bags.

Recommendations

Members are reminded of guidance document Guidance on open parachute type underwater air lift bags, which addresses the initial and periodic examination, testing, certification and maintenance of underwater type bags (cylindrical totally enclosed, closed and open parachute bags) used to lift submerged objects and also addresses the operational use of open parachute type lift bags and the safety precautions that should be taken during their use.

Latest Safety Flashes:

MAIB: Catastrophic engine failure and subsequent fire

MAIB has published Accident Investigation Report 10/2026 into a catastrophic failure of a diesel generator engine on board the vessel Kommandor Susan.

Read more
BSEE: Compressed gas cylinder hazards

BSEE has published Safety Alert 516, relating to potential risks involving compressed gas cylinders.

Read more
MSF: dropped object inside vessel tank

MSF have published Safety Alert 26-05 relating to a tank cleaning machine coming lose and falling within a tank on a vessel.

Read more
Uncontrolled movement of cargo

During offshore cargo operations alongside a rig, a single pipe loaded on deck shifted due to vessel motion and swell conditions.

Read more
Positives – rubber seals on hatches, securing of shackle pins, fuel sample box

A Member reports a few positive findings.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.