Near miss: Uncontrolled movement of gangway

  • Safety Flash
  • Published on 1 July 2019
  • Generated on 19 February 2026
  • IMCA SF 15/19
  • 2 minute read

A vessel gangway moved in an unplanned way and could have been lost overboard.  

What happened?

The incident occurred when the starboard gangway was under maintenance; the upper part of the turning platform had been removed earlier for maintenance. As a result, the gangway ladder was not connected to the turning platform. The ladder was secured with bolts.

In order to repair a corroded part of the fixed gangway platform, a welder secured the forward part of the gangway with rope. Then he loosened the securing bolts and gave a little slack on the gangway wire. 

At that moment, the forward rope slipped off and the forward tip of gangway fell 2-3m from where it was secured. The aft tip of the gangway ladder was hanging by the gangway wire and securing rope. The forward part of the ladder was approx. 2-3m lower. The gangway wire and securing ropes on the aft part prevented the gangway from further falling over to the side.

Other crew immediately brought chain blocks and other equipment to secure and recover gangway ladder back in to the place.

What went wrong?

What ought to have been simple, straightforward and safe maintenance turned into a near miss. Two crew members were busy with the task and neither of them thought that anything could go wrong.

What was the cause?

Human error:

  • inadequate attention to detail

  • inadequate job preparation

  • inadequate supervision.

What lessons were learned?

Reiterate the importance of safety awareness at the highest level with each and every job – the lesson is that things can go wrong with the most straightforward and ‘routine’ jobs. Complacency is to be guarded against.

Latest Safety Flashes:

Fall from height during mooring due to rope tension reaction

Rope became entangled with the propellor during mooring operations of a tanker causing the operator to lose balance and fall onto the lower platform.

Read more
Missing protection – progressive wear on hydraulic hoses causes damage

During an inspection, several hydraulic hoses and fuel hoses were found in direct contact with surrounding surfaces and sharp edges.

Read more
Small engine room fire – flammable object ignited

While ramping up the starboard main engine, a small flammable foreign object ignited.

Read more
Positive: damage to Fast Rescue Craft davit wire rope caught before failure

During routine checks, it was observed that the FRC davit wire rope had a visible fracture at the socket termination area.

Read more
BSEE: Miscommunication and trapped pressure causes injury during valve maintenance

BSEE has published Safety Alert 509 relating to a gas release incident on an offshore platform.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.