Important safety notice for users of Crosby S-1326 18/20mm Shur-Loc Hook with 16t WLL – PN 100434

  • Safety Flash
  • Published on 25 July 2019
  • Generated on 14 September 2026
  • IMCA SF 18/19
  • 2 minute read

IMCA has received a Safety Notice from Crosby.

IMCA has received the following from Crosby:

important safety notice from Crosby

July 19, 2019

Dear Valued User of Crosby Products:

THE CROSBY GROUP has determined the above listed hook assemblies may have a condition that can reduce the ultimate load capacity.  Although the hooks have successfully passed proof load testing at the factory prior to shipment, the hook shank threads may have an issue that is exacerbated by corrosion, and continued use may result in loss of load, property damage, severe injury, or death.

By use of the Production Identification Code (PIC) symbols appearing on the product, we have determined the 18/20mm size of S-1326 Shur-Loc Hooks with PICs 9SB, 9SC, and 9SD shown on the latch may have this condition.  See Figure 1 below indicating the position of the PIC on the hook latch.  No other PICs are part of this Important Safety Notice.

Please identify any 18/20mm S-1326 Shur-Loc Hooks with PICs 9SB, 9SC, and 9SD on the latch, to have the nut removed for inspection of the latch external threads.  These hook assemblies have a removable coiled spring pin nut retention device to allow periodic inspection of the load bearing threads.  Below are instructions for nut removal, inspection, and reassembly.  If there are no tools or resources available to perform the disassembly and inspection at the hook location, arrangements can be made to have the hooks returned to a Crosby Distributor for inspection.  Any hooks with non-conforming threads are to be immediately removed from service and returned to Crosby, through a Crosby Distributor.  Hooks with proper threads are acceptable for reassembly and continued service.

If it is determined during inspection that the hook threads are non-conforming, please make arrangements to return the hook for replacement.  To return these products, please contact your Crosby Distributor.  For more information concerning this Important Safety Notice, contact Technical Support at 1-800-772-1500.

Please inform your customer(s) of this Important Safety Notice, or if you know of other users of the 18/20mm S-1326 Shur-Loc Hooks, please pass this notice on to that user, company, or firm.

We regret the inconvenience this may cause you and your organization and thank you for your cooperation.  We are committed to providing you with the absolute best in Crosby quality.

Sincerely,

THE CROSBY GROUP

disassembly / inspection / assembly instructions for 18/20 mm S-1326 Shur-Loc hooks

Latest Safety Flashes:

Shoulder injury during intrusive work on pressurised hydraulic system

A hydraulic technician sustained a left shoulder injury during maintenance on a known small leak on a main hydraulic pressure line.

Read more
Galley fire alarm during diving operations

There was a galley fire alarm during active surface-supplied diving operations.

Read more
Unauthorised firing of rocket line

Without warning or agreement, Line Throwing Apparatus (LTA) was discharged by the tanker deck crew, splitting into two parts.

Read more
Unauthorized modification of main engine fuel pump linkage

An unsafe and unauthorized modification was identified on the main engine high-pressure fuel pump linkage arrangement.

Read more
Mooring rope caught in stern thruster

Confusion whilst unmooring as it was being prepared for departure from port, led to mooring ropes being caught in the stern thruster.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.