Collision between vessels

  • Safety Flash
  • Published on 3 October 2016
  • Generated on 13 July 2026
  • IMCA SF 25/16
  • 3 minute read

A Member has reported an incident in which there was a collision between a survey vessel and a pipe-carrying vessel.

What happened?

The incident occurred during vessel manoeuvring inside an anchor pattern. A survey vessel was instructed by a pipe laying barge to proceed towards the pipe-carrying vessel which was tied up alongside the barge, and then to moor alongside to complete a crew change. Upon entry of the 500m zone, the survey vessel was travelling at a speed of 4 knots maintaining a direct heading toward the barge. This was necessary because of the location of the mooring lines for the barge anchor pattern.

The Chief Officer attempted to slow down and change the heading on a distance of about 200m from the moored pipe-carrying vessel but identified the inability to alter the azimuth direction. The vessel Master, on taking command, attempted to alter the course of the vessel using the bow thrusters but to no effect. The survey vessel subsequently made contact with the pipe-carrying vessel causing some damage.

Vessel damage
Vessel damage

Our member’s investigation noted the following:

  • There was a loss of control over both azimuth thrusters:
    • Potentially the autopilot system engaged due to some mechanical failure or to human error
    • Neither the manufacture’s representatives or service engineer, nor the investigation team could advise on the definite cause.
  • A potential contributory factor was design deficiency:
    • One single switch controlled both ‘independent’ steering systems
    • Autopilot option overrode both azimuth thrusters, with no automatic disengagement available
    • When the autopilot is engaged it is not visually apparent to the operator
    • The ergonomics of the bridge console layout could potentially result in an alternative identical switch in the same vicinity as the autopilot switch (in this case, the gyro selector) being operated.
  • The 500m zone vessel speed requirements were not followed – despite the requirement for a maximum vessel speed of 2 knots in this particular safety zone, a speed of 4 knots was maintained for most of the distance, with further and possibly consequent failure to stop the vessel in close proximity to barge (around 200m away).
  • Company requirements for vessel heading were not followed – procedures forbade the use of offshore installations as navigational waypoints. The bridge crew on the survey vessel steered directly towards the barge.
  • The incident was not reported to the company ashore in a timely way or through appropriate and proper channels.

Latest Safety Flashes:

Severe injuries following falling off a freight container

A truck driver slipped and fell from a container leading to severe injury.

Read more
Watertight doors left open

Watertight doors in the Engine Room and fire doors in the accommodation were observed open on several occasions during a management audit.

Read more
Crew member injured during mooring operation

A crew member used their foot to slow down a running mooring rope, causing them to fall to the deck.

Read more
Worker got something in the eye – safety glasses slightly askew

A workers safety glasses were slightly offset (creating a small gap) which allowed a fragment of hot slag to get in his eye.

Read more
Fire in tumble dryer

A fire was discovered within one of the vessel laundry dryers.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.