Line of fire near miss during lifting operations

  • Safety Flash
  • Published on 18 December 2023
  • Generated on 11 August 2026
  • IMCA SF 29/23
  • 2 minute read

A member of the deck crew member put themselves in the line of fire during landing of a structure  on the back deck of a vessel.

What happened?

The installation aids (bumper bars) were insufficient to stabilise the load, resulting in the structure being landed narrowly missing the individual, and damaging an adjacent container. 

The bumper bars were a critical barrier for keeping the banksman safe on the walkway but as they were not spaced far enough apart for the structure, they allowed a rotational movement of the load.

Snapshots from CCTV footage of near miss showing swinging load impacting container

Snapshots from CCTV footage of near miss showing swinging load impacting container

What went right?

  • Before landing the structure, the area had been barriered off and non-essential personnel removed from the area.

  • All the containers were checked to ensure no-one was working inside them during the lift.

What went wrong?

  • The individual was focused on landing the structure in a tight space and was relying on the bumper bars to keep him safe in the event of unplanned movement of the structure.

  • Even though the design of the installation aids (bumper bars) was within the vessel’s design code, they were not there to protect people, but there as aids to landing and moving structures around the deck without damage. As they were not designed for personnel protection, the distance between them was not considered.

Actions

  • There was a general misconception that installation aids can be used as personnel protection devices, but this is not their design nor their appropriate use.

  • Moving the counterweight location and bumper bars was seen as an improvement by the vessel team and therefore they did not go through a Management of Change (MOC) process. Even perceived improvements may have negative consequences and need to be managed.

  • Despite all the good work done in pre-job planning, the banksman still put himself in the line of fire. In hindsight, this area should have been a complete no-go zone.

  • Take into account when planning work, the difference between “work as imagined” and work as actually done.

  • Remain aware of your close environment and understand that during lifting activities, the exclusion zone may change.

  • Review tasks where installation aids are being relied on for personnel protection. Should a wider exclusion zone be put in place for these tasks?

Latest Safety Flashes:

MAIB: Catastrophic engine failure and subsequent fire

MAIB has published Accident Investigation Report 10/2026 into a catastrophic failure of a diesel generator engine on board the vessel Kommandor Susan.

Read more
BSEE: Compressed gas cylinder hazards

BSEE has published Safety Alert 516, relating to potential risks involving compressed gas cylinders.

Read more
MSF: dropped object inside vessel tank

MSF have published Safety Alert 26-05 relating to a tank cleaning machine coming lose and falling within a tank on a vessel.

Read more
Uncontrolled movement of cargo

During offshore cargo operations alongside a rig, a single pipe loaded on deck shifted due to vessel motion and swell conditions.

Read more
Positives – rubber seals on hatches, securing of shackle pins, fuel sample box

A Member reports a few positive findings.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.