Comments from the report:

An AVR problem in diesel generator No. 1 engine caused an over voltage in the system.  Due to increased voltage, the standby machine could not be brought online, and the switchboard required a controlled blackout.  After this, many alarms from Network B were observed due to the supply being interrupted.  An hour later, there was a total loss of network communication affecting many field stations together with loss of DP communication to all thrusters, which caused the vessel to drift off.  The probable cause was accidentally resetting network A, when trouble shooting of network B was taking place.

Further investigation of the overvoltage issue found a 3-phase breaker was faulty to engine No.1; the breaker was replaced by an onboard spare.  The DP system manufacturer concluded that the vessel was operational as designed, indicating a possible human mistake by rebooting network A.

Considerations of the IMCA Marine DP Committee from the above event:

The vessel instigated a DP yellow alert whilst a fault was investigated. Considering the weather conditions and nature of investigation the vessel should have either abandoned operations or been fully prepared to do so.

Given the circumstances, it is evident the vessel returned to normal operations too quickly and whilst reinstatement of the system was still in progress.  The root cause of the incident was not given in the report, but it is evident that work involving the resetting of the network caused the loss of DP communication with the thrusters and subsequent position excursion.  While total network failure and subsequent drift off represents a DP incident, the initial failure of the AVR only represents an undesired event.

DP Event

Published: 18 February 2019
Download: IMCA DPE 01/19

Classification:
Submit a Report

The following case studies and observations have been compiled from information received by IMCA. All vessel, client, and operational data has been removed from the narrative to ensure anonymity.

Case studies are not intended as guidance on the safe conduct of operations, but rather to assist vessel managers, DP operators and DP technical crew in appropriately determining how to safely conduct their own operations. Any queries should be directed to IMCA at [email protected]. Members and non-members alike are welcome to contact IMCA if they have experienced DP events which can be shared anonymously with the DP industry.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.