Cargo shifted during heavy weather

  • Safety Flash
  • Published on 10 February 2022
  • Generated on 14 November 2026
  • IMCA SF 04/22
  • 2 minute read

Moderate to heavy rolling caused strapping holding stacks of cargo to break.

What happened?

Cargo broke loose in heavy seas on a vessel in transit. Moderate to heavy rolling caused strapping holding stacks of cargo (metal beams) to break, causing the stacks to collapse.  Seven stacks collapsed or shifted, and a further three stacks moved to a lesser degree.  There was no structural damage to the vessel or to other cargo.  The vessel altered course and the collapsed / shifted stacks were re-secured with extra chain lashings.

Photos of shifted cargo

Showing stacks of beams having shifted

Photos of shifted cargo

1) beams tied with thin metal ties, 2) broken metal ties, 3) metal-metal contact, 4) Beams shifted after rolling

Findings

  • The vessel was transiting at 16 knots following a route recommended by a respected weather information service provider. Winds Force 5-6, Swells 5/6, rolling moderately to heavily at times.
  • There was adequate warning (at least two days) of the impending heavy weather; there had been a Bridge Team Meeting before departure at which impending weather was discussed.
  • A “heavy weather checklist” had been filled and precautions taken; lashing checks were carried out daily after departure and lashings tightened as required.
  • No timber blocks were placed between/around the stacks to make them a unified block to ensure less possibility of movement. Also, the cargo was loaded on just two wooden blocks which were part of the stack and directly on deck. 

What was the cause?

Our member noted the following:

  • Immediate cause
    • The beam stacks (each over 9000kg and length: 4.5 m x width: 1.7 m x height: 1.9 m) were not loaded or lashed as per the Code of Safe Practice for Cargo Stowage and Securing (CSS code) for such cargo.
  •   Causal factors
    • Inadequate communication – there was ineffective communication between vessel and charterers.
    • Inadequate supervision – there was misjudgement of vessel movement and external force (wind, wave, and swells),
    • Lack of experience in loading / lashing such type of cargo at the Port of Loading.

Actions

  • Further training on proper/effective lashing and securing of cargo.
  • Discussion end education on need for vigilance and close supervision when loading.
  • Additional lashings to be in place in certain weather conditions.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.