Near-miss: Person fell from boarding ladder

  • Safety Flash
  • Published on 8 June 2012
  • Generated on 16 September 2026
  • IMCA SF 05/12
  • 2 minute read

A Member has reported an incident in which a person slipped from the barge boarding ladder and almost fell into the water.

What happened?

During a short boat transfer from the accommodation vessel to the barge, the anchor handling tug moored alongside the barge and the crew transfer commenced. The transfers were performed in an orderly fashion with the personnel patiently waiting for the best moment to step from the anchor handling tug (AHT) on to the ladder of the barge. However, one person missed his step, lost his grip and fell between the AHT and the barge. He landed on one of the tyre fenders and was immediately helped inboard by other passengers still on the AHT. The transfer operation was aborted immediately and the AHT moved to the other (lee) side of the barge. The man that fell suffered only a superficial scratch on the right arm.

The investigation revealed the following:

  • Existing project-specific personnel transfer protocols/procedures were not followed.
  • There was inadequate allocation of resources. The dedicated crew tender was being used for other purposes at that time, resulting in the use of an AHT to perform a crew tender job.
  • Precautionary measures already identified in the hazard identification (HAZID) (i.e. suitable embark/disembark arrangements) were not installed.
  • The job should have been stopped under ‘stop work’ authority, but nobody did so.

The following measures were put in place to prevent recurrence:

  • Re-write of the project specific protocol/procedures for personnel transfer.
  • Nomination of a ‘marine traffic controller’ to perform the following tasks
    • observe all vessel movements to and from the barge
    • provide advice on which side of the barge to moor up
  • Reinforce the ‘stop work’ authority in project documentation and project induction.
  • Determine if additional training is required for personnel engaged in vessel-to-barge transfer.

For further information on this subject, Members may wish to refer to IMCA HSS025 Guidance on the transfer of personnel to and from offshore vessels and structures.

Latest Safety Flashes:

Shoulder injury during intrusive work on pressurised hydraulic system

A hydraulic technician sustained a left shoulder injury during maintenance on a known small leak on a main hydraulic pressure line.

Read more
Galley fire alarm during diving operations

There was a galley fire alarm during active surface-supplied diving operations.

Read more
Unauthorised firing of rocket line

Without warning or agreement, Line Throwing Apparatus (LTA) was discharged by the tanker deck crew, splitting into two parts.

Read more
Unauthorized modification of main engine fuel pump linkage

An unsafe and unauthorized modification was identified on the main engine high-pressure fuel pump linkage arrangement.

Read more
Mooring rope caught in stern thruster

Confusion whilst unmooring as it was being prepared for departure from port, led to mooring ropes being caught in the stern thruster.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.