Fatal fall from collapsing scaffolding on a merchant vessel
- Safety Flash
- Published on 11 March 2022
- Generated on 16 September 2026
- IMCA SF 06/22
- 2 minute read
Jump to:
A sailor was killed in a fall from collapsing scaffolding.
What happened?
The Hong Kong Merchant Shipping organisation reports an incident in which a sailor was killed in a fall from collapsing scaffolding. The bosun and AB were assigned to rig a scaffolding to the maintenance platform which was bolted to the gusset plates at the boom of the port side hose handling crane (the boom) on the main deck.
When the bosun and AB were working on the maintenance platform of the boom setting the scaffolding, the platform and the scaffolding suddenly collapsed at the same time. The bosun fell onto the platform railing and he climbed back to the boom safely. Although the AB had worn a safety harness and anchored it to the platform railing in the form of a choker hitch, the lanyard of the safety harness snapped and failed to prevent him from falling from the platform at a height of about 7.9 metres onto the main deck. The AB was declared dead later on the same day.
What was the cause?
Investigation revealed that the securing bolts of the platform support were seriously corroded and failed to support the weight acting on it, resulting in the collapse of the platform.
The investigation also identified other contributory factors:
- Poor risk assessment.
- Poor supervision of scaffolding work being carried out by the crew without training record of scaffolding.
- Non-compliance of the configuration of the scaffolding including the non-compliance of its structural steel rods with a generally recognised standard.
- Insufficient safety instructions or guidelines for scaffolding work provided by the management company of the vessel.
- Inappropriate maintenance of the safety harness.
- Insufficient training on using personal protective equipment.
Related Safety Flashes
-
IMCA SF 17/17
13 July 2017
-
-
IMCA SF 04/13
15 February 2013
-
IMCA SF 15/13
23 September 2013
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.