A yard worker fell 4 m from the main deck to a mezzanine deck, suffering a compression fracture in his right ankle.

What happened?

During a yard visit, pieces of grating were being manually lowered with a rope down through an opening on the main deck. The opening on the main deck was barred off by a scaffold. No fall protection was requested by the people on the main deck.

Two workers should have been on the main deck and two on the mezzanine deck. The workers on the mezzanine deck were wearing fall protection. However, at the time of the incident there were three workers on the main deck, and one worker on the mezzanine deck.

A piece of grating got stuck on an edge on the main deck. This was observed by a co-worker who happened to be nearby. He intervened in the work operation. The workers on deck shifted the grating about 15 centimetres. As the grating shifted, the new worker continued to hold onto it, lost his balance and fell.

The injured worker was a part of the scaffolding team but was not a part of this planned operation. He decided to help his co-worker. He was wearing a fall arrester but did not clip into an anchor point.

173 520X381

What went wrong?

  • Attitude and behaviour – the injured person and the work team showed lack of safety awareness.

  • Non-compliance with personal protective equipment (PPE) – the injured worker was wearing a fall arrester but didn’t clip on to an anchor point. Also, whilst the gratings were usually handled manually, there were taglines attached, but these were not used.

  • Competence and experience – the injured worker had worked as a scaffolder at the yard for years, had experience and training in scaffolding and working at height, and possessed competence certification. All the work team including the injured person were experienced in working at height.

  • Language – the injured worker spoke neither English nor Norwegian. Translation was conducted by co-workers. This yard routinely employs foreign workers with limited or no skill in English, although laying down rules for sub-contractors on how such workers were to be deployed.

  • Teamwork/communication – the investigation team has not been able to conclude if the worker was asked to support, or if he intervened on his own initiative. Different versions of the story have been raised in interviews.

  • Management and supervision – the work team was wrongly organised. There were four workers in the work team, there were supposed to be two workers on the main deck and two workers on the mezzanine deck for this operation. At the time of the incident there were three workers on the main deck, and only one worker on the mezzanine deck.

  • Safety systems – a Permit to Work and Toolbox Talk had been conducted, and the injured person had been a part of the toolbox talk (see earlier remark about language). The foreman for this work considered it to be known to the work team, so no specific job safety analysis took place, and there was insufficient focus on the shipyards’ “We Care” safety campaign, as supervisors and co-workers did not pay attention to the injured person not using appropriate working at height equipment.
  • Immediate cause: the injured worker rushed into a work situation he was not supposed to be a part of. He did not consider the risk in the operation and did not secure his fall arrest to an anchor point.

  • Underlying causes of the Incident: the injured worker did not comply with working at height standards and did not pay attention to the risks in the work situation.

  • Root Causes: the investigation concluded that these were weaknesses in safety awareness and management of work in the actual situation.

What lessons were learnt?

  • Ensure closer follow up of yard to ensure compliance to safety awareness.

  • Executive (high level) commitment to safety is paramount for building a strong safety culture – particularly when multiple organisations are working together in a shipyard.

Members may wish to review Guidance on safety in shipyards.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.