Cutting torch hose separates from flame arrestor

  • Safety Flash
  • Published on 4 June 2014
  • Generated on 14 July 2025
  • IMCA SF 08/14
  • 2 minute read

An incident has come to IMCA’s attention in which an Oxy-Acetylene cutting torch hose separated from the flame arrestor, resulting in a flashback.

What happened?

The incident occurred during welding modification of stabbing guides inside a pile driving hammer. While cutting a steel plate with a torch, the pipefitter experienced a flashback of flames as the connection of the hose suddenly came loose. Immediately the fire watch used the standby fire extinguisher and put out the flames. The men stopped the job and called for the supervisor. The pipefitter was unharmed and no property damage occurred.

The investigation revealed the following:

  • Immediate cause: was identified as inadequate repair using unsuitable techniques and methods. The inside diameter of the hose was larger than the one suited for this type/size of nipple so tape was used to make up the difference. The clamp could not tighten against the barb on the nipple and when the tape warmed up the hose and clamp slipped off over the barbed end.
  • Root Cause: was use of miss-matched materials that were inadequate for the task. The correct size hoses with clamps were ordered but were unavailable at the time. An improvised repair was made using tape to secure a tight fit.

Our member took the following corrective actions:

  • Inspect all torch hoses and remove all with this type of improvised connection.
  • Crew trained and provided awareness in proper materials and procedure.
  • A ‘safety stand down’ was conducted on-board to reiterate the importance of pre-job inspection and carrying out the job using the safest methods and materials.

Safety incidents involving pressurised gas fittings, oxy-acetylene cutting equipment and gas cutting in general are quite commonplace.

Latest Safety Flashes:

LTI: Hand injury during capstan maintenance

A crew member was injured when their hand was trapped between a wire clamp on the underside of the capstan and the deck.

Read more
High potential incident: Worker injured when opening a flanged assembly

A member of a team of workers dismantling subsea emergency shutdown valves (ESDV) on deck, was badly injured when hit by parts of a valve which were ejected with force.

Read more
Near miss: worker suffers electric shock

A member of a vessel crew suffered a mains electric shock when working on a crane pedestal.

Read more
Unsafe use of electrical equipment in cabins

Crew members were observed inserting 2-pin electrical chargers directly into 3-pin vessel sockets to power their personal equipment.

Read more
UK HSE: load falls from lorry and kills cyclist

A metal heat exchanger, weighing over 2.5 tons, fell from a lorry and killed a passing cyclist.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.