A Member has reported that a DP diving support vessel was in the midst of a diving operation when it rapidly moved off location by some 107 metres from the work site.

What happened?

Two divers were locked out at the time. Diver 1 was working while diver 2 was at the bell on the guide weight. The effect of the force was such that diver 1 could not return to the bell on his own, nor could Diver 2 manage to haul him back via the umbilical. Once recovered to the bell, the diver, overcome with carbon dioxide toxicity as a result of overbreathing inside the helmet, began to vomit almost immediately upon having his helmet removed. He was settled down, put on BIBS and gradually recovered.

Our Member’s investigation revealed the following:

The company’s investigation concluded that the ‘run off’ was attributed to the effects of a Soliton. By the simplest definition, solitons are subsea waves of significant risk potential for diving and ROV operations. Detection by slight surface irregularities with either the naked eye or radar is possible. They tend to be seasonal and, although their direction of travel is somewhat predictable, reliance on direction alone as a precaution is not advised.

Recommendations

The company carried out a risk assessment and made recommendations for operating in waters of known Soliton activity as follows:

  • When feasible, schedule work for low season Soliton activity.
  • Seek local knowledge and experience with regards to expected activity levels.
  • The vessel heading should be into the direction of the most likely Soliton approach regardless of optimum heading for DP or other environmental considerations.
  • A dedicated competent person shall remain on radar watch at all times during critical work phases.
  • Radar shall be tuned to optimise potential to see approaching Soliton, setting the sensitivity/gain to reduce wave scatter.
  • Break away or quick release lines should be installed on all down-lines.
  • Facility to overboard the supply end of tool umbilicals with buoys attached should be provided.
  • Clear runs for overboard lines on deck should be established and maintained.
  • When feasible, two divers should be working together at all times.
  • The DP operator is to be alerted when the divers have entered a structure or confined area.
  • Optimise control at subsea structure positions.
  • Divers should be immediately alerted of all anomalies.
  • No diver ‘turn arounds’ if attached to fixed structures in known Soliton areas.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.