Near-miss involving diver’s neck dam
- Safety Flash
- Published on 2 September 2003
- Generated on 11 April 2026
- IMCA SF 12/03
- 4 minute read
Jump to:
We were recently provided with and issued details of a ‘high potential’ near-miss incident involving failings in a saturation diver’s personal protective equipment.
What happened?
This information was issued as part of safety flash under the heading ‘Near-miss involving diver’s neck dam‘. Feedback from equipment manufacturers has highlighted the need to make certain clarifications as it was felt that the wording of the flash may have been misleading.
Divers were in saturation, with one diver in the bell carrying out bell checks and two divers dressed and making final preparations prior to entering the bell. One diver was placing his neck dam over his head when he heard ‘something’ fall. Suspecting something untoward, he removed the neck dam to inspect it in detail. He observed that two of the four retaining screws in the rear hinge tab plate (at the back of the neck dam) were missing (with one screw ¾ out and the other secure). The screw ¾ out would not tighten and it was found, on close examination that the thread had stripped. The other screw was checked and found to be okay. The neck dam was locked out to technicians and the supervisor for further inspection and investigation.
An inspection highlighted the following findings:
- The neoprene sleeve to the neck dam had not been fitted according to company procedures.
- The retaining lug was loose and about to fail.
- Of the four retaining screws, all of which should be in position and tight, two were missing completely and one was missing its locking washer and was loose.
- Specialist adhesive (company procedure) had not been applied to the screws.
- The tapped hole, which should have held the missing screw, was found to have a stripped thread.
- The neoprene neck dam had not been positioned/fitted as per the company’s procedures.
- It was obvious that the screw had been forced through the neoprene material, as there were neoprene ‘plugs’ found in the base of each screw hole. Any torque applied to the screws would have given a false indication of tightness.
The root causes were identified as:
- Unauthorised maintenance (neoprene neck dam not fitted as per company procedures).
- Failure to follow or understand company procedure that only technicians trained in dive hat maintenance are allowed to carry out work to dive hats and associated equipment (and/or a failure to properly communicate the company procedures to the workforce).
The company involved has identified the following corrective actions:
- Briefing of divers that only authorised personnel are to carry out repair and maintenance on diving hats.
- Display of signs on entrances to the hat maintenance workshop to the effect that ‘only authorised personnel are to carry out repair and maintenance on diving hats and neck dams’.
- Display of signs on hat and neck dam storage racks in the hat maintenance workshops to the effect that ‘only authorised personnel are to carry out repair and maintenance on diving hats and neck dams’.
- Control stock of spare/replacement neck dams – now held under lock and key so that only hat maintenance technicians have access.
The previous safety flash stated that placing of the neoprene directly over the rear hinge tab retaining plate was an incorrect procedure. Members should note that this statement should have clarified that this method of fitting the neoprene was incorrect only in that it was not in compliance to the member company hat maintenance procedures and this statement was not intended to imply that other methods of fitting the neoprene neck dam practiced by and in accordance with other member companies established hat maintenance procedures or procedures issued by manufacturers/suppliers were therefore incorrect.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.