Dropped object near-miss

  • Safety Flash
  • Published on 17 August 2009
  • Generated on 7 November 2026
  • IMCA SF 12/09
  • 3 minute read

A Member has reported an incident in which an object was dropped whilst being lowered to divers on the seabed. 

What happened?

The vessel was working in waters over 100m depth when a stainless steel toolbox was being ‘routinely’ deployed to divers on the seabed. The deployment of the toolbox was stopped at 98 m (the short mark) and the divers were advised to retrieve it. However, on arrival at the pennant hook they reported the toolbox missing.

A search for the toolbox was made using an ROV and it was found on the seabed directly below the initial deployment point, from where it was recovered to deck. No one was injured and no equipment was damaged.

The incident was immediately reported to the offshore construction manager, who temporarily suspended operations. Initial inspection of the toolbox, the deployment pennant and hook onboard the vessel rigger did not identify any defects. However, the toolbox had been deployed by attaching it to the crane pennant hook by a section of long link chain bolted to the toolbox.

Toolbox, chain and crane pennant hook

toolbox, chain and crane pennant hook

Detail of small diameter chain used

detail of small diameter chain used

What were the causes?

Investigation revealed that the small diameter long link chain had passed through the wear gap in the hook when the toolbox was transiting through the splash zone, allowing the toolbox to drop.

The hook was certified and the wear was within design and wear specification limits.

The company noted that:

  • The incident had the potential to cause serious injury to divers and was reportable to local regulatory authorities.

  • The incident happened during a ‘routine’ task where ‘custom and practice’ methods were accepted without challenge.

  • The toolboxes were manufactured in-house and not fabricated to any design criteria or control processes. No engineering drawings were available.

  • Important factors not considered during the fabrication of the toolboxes included:

    • Lifting accessory requirements

    • Effects of splash zone dynamics

    • There was no certification or safe working load of the lifting points or chain.

    • The type of long link chain being used was unsuitable for deployment.

    • Laying the chain over the throat of a hook was improper rigging practice.

  • Neither the requirements of an existing risk assessment nor company control processes were complied with.

  • Perception and awareness of the potential risks involved in this task were low:
     
    • Failure to recognise the toolbox as a lifting accessory.

    • Failure to recognise that part of the lifting equipment was uncertified, not properly designed or fit for the purpose of lifting operations.

  • Worksite safety culture was not fully effective:

    • Improper rigging practices were employed.

    • Deployment method was not challenged by rigging team or worksite supervisors.

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.