Fatality during maintenance of elevator lift

  • Safety Flash
  • Published on 1 November 2001
  • Generated on 11 April 2026
  • IMCA SF 13/01
  • 2 minute read

The following fatality, which occurred during a routine maintenance task on an elevator lift installed on a rig, has been reported to IMCA. 

What happened?

The task being undertaken was to change the wire that raised and lowered the lift. During the operation, the securing arrangement used for this maintenance task failed and the lift fell over 100 feet to the bottom of the lift shaft. The Barge Supervisor was on top of the lift when it fell and he died of his injuries.

At present, the exact details of what happened have not yet been fully established, but the company concerned and the UK Health & Safety Executive (HSE) are conducting detailed investigations into the incident.

The company concerned has undertaken to carry out the following actions:

  • Maintenance activities are to be reviewed and risk assessed to ensure that there are adequate controls in place before the start of a job. This may mean that additional assessment procedures will need to be drawn up for more complex activities.
  • The requirements of the UK Region Permit To Work (PTW) procedures are to be studied. Department heads, in conjunction with the OIM shall review and, if appropriate, reinforce the PTW system for maintenance activities.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.