Diver reports unwell post-dive: non-decompression illness

  • Safety Flash
  • Published on 14 August 2025
  • Generated on 7 April 2026
  • IMCA SF 14/25
  • 2 minute read

A diver experienced a dizzy spell about one hour after completing a diving operation

What happened?

The incident occurred after the 50 year old diver undertook a dive to 87 feet with a bottom time of 31 minutes. The diver was decompressed on a USN rev 7. 90/33 'freetime dive’ and reported well upon surfacing. About one hour later, on deck, the diver called out for attention reporting extreme nausea and dizziness. 

What was the response?

The diver was immediately recompressed in the chamber on a USN treatment table 6 as per company procedure with a Diver Medic Technician (DMT) with him in attendance. The DMT performed a full physiological and neurological examination and blood sugar levels were taken as a precautionary measure. The diver’s blood sugar levels were observed to be dangerously high.

A hyperbaric physician was contacted and following their advice, decompression illness was ruled out and hyperglycaemia was suspected, as the examination pointed towards a diabetic response. Treatment table was switched to a Table 5 to reduce chamber time so that the diver could have his blood sugar levels brought under control at the earliest opportunity.

After 90 minutes the diver and DMT were able to leave the chamber. The diver was evacuated ashore for further medical attention. 

What was the problem?

It was later reported that the diver had an unreported diabetic condition for which he was not taking any traditional therapy but was seeking alternative natural methods.

What were the recommendations?

  • Healthy eating ‘campaign offshore’ & Welfare Improvement
    • Crew should engage with vessel medics for nutritional advice.
    • Crew should be motivated to declare medical issues before coming offshore.
    • Crew need to be confident that their jobs are not at risk because of declaring their medical conditions.
  • Improve crew education on common non-communicable diseases like Diabetes and Hypertension so that they can easily spot when they have symptoms.
  • Encourage use of gym when offshore – physical and mental fitness needs to be encouraged and looked after.
  • Look closely at ensuring how divers maintain their fitness and Body Mass Index (BMI) to an acceptable level.

Members may wish to refer to:

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.