BSEE: Electromagnetic lifting device dropped steel plate

  • Safety Flash
  • Published on 4 September 2025
  • Generated on 6 March 2026
  • IMCA SF 16/25
  • 3 minute read

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 500 relating to a defective lifting device dropping a steel plate during drilling operations.

What happened?

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 500 relating to a defective lifting device dropping a steel plate during drilling operations, and two persons were injured. The incident occurred while transferring a partial 3/8” (95mm) steel plate sheet using a magnetic lifting device. During the lift, the steel plate unexpectedly detached from the magnet and fell approx. 1.2m, landing on top of both individuals’ left feet. Both personnel reported bruising and swelling and were evacuated for medical evaluation. 

What went wrong?

  • Investigation revealed that the magnetic lifting device was ineffective due to wear and tear;
  • Manufacturer tests indicated that wear damage to the lifting device could create air gaps, preventing it from functioning effectively;
  • The job safety analysis (JSA) conducted before the operation did not adequately address the specific hazards associated with the lifting equipment. While the JSA noted general hazards, it failed to identify the risk of the plate prematurely releasing from the lifting device;
  • BSEE notes additionally that:
    • “A critical factor in this incident was a failure to stop work and review the JSA before proceeding with the lifting operation” and that this reflected a safety culture where crew members did not feel empowered to halt operations to reassess potential hazards;
    • There was a perception of haste among the personnel, which may have contributed to their decision to proceed without thoroughly discussing the risks involved. This urgency to complete tasks underscores the need for improved communication and adherence to safety protocols.
IMCA SF: BSEE: Electromagnetic lifting device dropped steel plate 1

Magnetic lifting device

IMCA SF: BSEE: Electromagnetic lifting device dropped steel plate 2

Steel sheet and incident area

Recommendations (BSEE)

  • Safety 
    • Encourage open communication among crew members regarding safety practices and adhering to established protocols.
    • Foster a culture of safety that encourages personnel to exercise stop work authority and discuss potential hazards whenever uncertainties arise.
    • Revise job plans to ensure that the team adequately addresses specific hazards associated with lifting gear and suspended loads.
    • Conduct thorough JSAs that include a comprehensive hazard assessment for all lifting operations.

  • Lifting
    • Ensure proper training on use of lifting equipment and the importance of confirming that all safety mechanisms are engaged before lifting operations begin.
    • Robust inspection programmes for lifting devices to ensure they are maintained in safe working condition and regularly evaluated for wear and tear.
    • A reporting mechanism for any observed defects or safety concerns related to lifting equipment.

  • Electromagnetic lifting devices
    • Even brief power spikes can disable electromagnets, leading to dropped loads. To prevent sudden loss of magnetization, implement procedures to monitor power stability and ensure that backup systems are in place.
    • Ensure there are procedures in place to prevent coils from burning out by limiting how long operators keep the  power on with electromagnetic lifting devices.
    • Turn off the magnets when they are not in use, especially if the magnets are not designed for continuous duty cycles.
    • Consider a pre-use inspection and load testing procedures for electromagnetic lifting devices.
    • Ensure the lifting surface is clean and free from debris, oil, paint, or rust, which can interfere with the magnet’s contact and reduce lifting capacity.

Members may wish to refer to:

·       IMCA HSS 019 M 187 LR 006 Guidelines for lifting operations

Latest Safety Flashes:

Dropped object: falling shim plate while lowering A-frame

During the lowering of the A-frame of the crane on a large crane vessel, a plate with a weight of 15kg, rolled out from the auxiliary inboard fleeting sheaves.

Read more
W2W gangway bumper damaged during demonstration

During testing to demonstrate emergency retraction, the movement of the vessel in the swell applied forces to the bumper, which caused the bolts to fail and the bumper to break off.

Read more
Towing wire parted

A vessel was towing a barge when the towing wire parted.

Read more
BSEE: Falling corroded crane component results in near miss

BSEE has published Safety Alert 511 relating to a near-miss dropped object incident on an offshore platform during the maintenance and inspection of a platform crane.

Read more
Cook temporarily trapped in freezer

A vessel cook was temporarily trapped inside a large walk-in freezer.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.