What happened?
The crane boom/knuckle had been lowered to deck to enable access to the main hoist sheave for inspection and maintenance purposes. The crane was powered down and the operator was not in the cab. During the inspection there was an uncontrolled movement of the knuckle section along the deck of approximately 30cm towards the crane pedestal.
The hydraulic cylinders in the main boom were not fully closed when the crane was stowed in this position; therefore the weight of the jib was able to overcome the friction on deck and thus caused the movement of the knuckle head across the deck. At the time of the movement the inspector had been positioned close to the equipment in order to gain access on either side for a complete overview.
A number of key lessons were drawn from this near-miss:
- Conduct such inspections and ‘routine’ maintenance with the crane stowed in dedicated parking position i.e. crane crutch.
- Ensure that the main boom cylinders are fully closed to avoid uncontrolled movement of crane jib.
- Follow approved procedures and always fully brief third party personnel during a toolbox talk prior to commencing the operation.
- Follow and adhere to the permit to work system, review and risk-assess specific tasks.
- Ensure that a complete and thorough shift handover is conducted at all times and strive to identify any hazards while the job is in progress; . Barrier off work-site and ensure all personnel are aware of the potential hazards.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.