Safe use of FIBC (Flexible Intermediate Bulk Container)

  • Safety Flash
  • Published on 6 July 2020
  • Generated on 14 November 2026
  • IMCA SF 20/20
  • 2 minute read

What happened?

A Flexible Intermediate Bulk Container (FIBC ) containing 36 sand bags weighing approx. 25 kg each was being lifted from the quayside to the vessel.

As the load was lifted to approximately 1 metre, there was a routine inspection of the load to check the handle loops and that the base of the bag was OK before lifting.

The FIBC was raised to 3-5 metres when a distinctive tearing / ripping sound was heard, it was then the FIBC handle and stitching tore and the 900 kg of sand bags fell onto the quayside. There were no injuries.

36 sand bags weighing 900 kg being lifted in a Flexible Intermediate Bulk Container fell 3-5 m to the deck when the FIBC handle and stitching ripped

What actions were taken?

Always
  • Inspect FIBCs prior to use, ensuring that they are:
    • free from damage that can compromise its strength
    • free from any UV degradation (due to sunlight exposure)
    • free from chemical damage
  • Lift following manufacturer and supplier’s instructions.
  • Ensure the landing area is clear of sharp and protruding edges.
  • Ensure the filled FIBC is stable and secure during transportation.
  • Store in a suitable location protected from UV radiation and rain (long periods of storage).
  • Pad out forklift forks when lifting through lift handles to eliminate sharp edges.
Never
  • Drag or push FIBCs.
  • Stop/start suddenly when lifting (shock loading).
  • Allow suspended load to swing uncontrollably.
  • Lift by steel wires or similar devices which may present sharp edges or rough surfaces.
  • Use an FIBC which has exceeded 2 years from the date of manufacture.
  • Lift over personnel.

Note: If there is any doubt about the integrity of the FIBC, replace the FIBC or use a metal transfer basket/half height.

Members may wish to refer to:

Latest Safety Flashes:

Cyber-attack on vessel

An oil tanker suffered a cybersecurity incident.

Read more
MAIB: Normalising of unsafe practice – fatal man overboard incident

MAIB have published Accident Investigation Report 16/2026 into a fatal man overboard incident on board a bulk carrier offshore Sweden.

Read more
Dust explosion in Bow thruster motor

Upon activation of the bow thruster, there was a loud explosion within the forward section of the workboat.

Read more
Dropped bulk bag during loading operations

A dropped object incident occurred during quayside lifting when a bulk bag failed due to incorrect loading.

Read more
Failure of sea-fastening on the leg of a jack-up barge

During a sea passage, prevailing sea conditions caused a jack-up barge to experience rolling and pitching motions.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.