LTI: person suffered serious crush injuries

  • Safety Flash
  • Published on 30 November 2022
  • Generated on 30 November 2026
  • IMCA SF 27/22
  • 2 minute read

During offshore drilling operations, a drilling assistant sustained serious crush injuries, resulting in several weeks away from work.  

What happened?

He was injured when he leaned out of the rooster box, between the guard railings, and was caught between the compensator carriage and the rooster box.

Diagram of position of crew

What went wrong?

  • No-one STOPPED THE JOB: people on the back deck did not challenge unsafe behaviour: people remained in the rooster box in between tool-handling operations.
  • There was inadequate management supervision – no-one verified and monitored compliance with the applicable rules, regulations and good practice.
  • Procedures were not adequately controlled, maintained, and shared.
  • Hazards associated with the tasks were not adequately identified and assessed in the preparation onshore, nor execution offshore.
  • There was a lack of means of communication and observation (such as audio comms and CCTV) to support the management of deck activities.
  • Previous lessons learned during other geotechnical drilling operations were not adequately captured in the drilling manual, shared and/or implemented on this project.

Recommendations and actions taken

  • Our member took the following actions and recommendations
    • Ensured that the procedures and work instructions supporting the operations were controlled, up to date, relevant to the operations and shared, ensuring that the team executing the operations were adequately familiarised.
    • Hazard identification tools  such as HAZOPS, HAZID, Risk assessment, Task risk assessment or SLAM (“Stop, Look, Analyze, Manage”) are critical in ensuring all stakeholders are aware of all the risks and mitigations, reducing the risk to “as low as reasonably practicable”.
    • Adequate communication is essential between employees and supervisors, and where required should be supplemented via electronic means.
    • Safety barriers and devices (e.g. railings) should not be bypassed or defeated.
    • Regularly reinforce messaging to ensure that in the event of any process change or where a hazard is identified, all of us are empowered to speak up and STOP THE JOB without fear of consequence or retaliation.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.