remove this or use for another sf

  • Safety Flash
  • Published on 1 March 2004
  • Generated on 7 April 2026
  • IMCA SF 02/04
  • 2 minute read

A mechanic had started a deck air compressor, when the sudden delivery of pressurised air through the delivery hose caused momentary snaking of the hose. 

What happened?

The mechanic acted in a calm manner and switched off the compressor immediately. Fortunately no one was positioned close to the coiled hose, so nobody was injured. Nothing was damaged.

The snaking hose had the potential to cause injury to personnel on deck.

During investigation, it was also noticed that the isolation valve’s handle was missing.

Before starting the compressor, the mechanic had not checked the delivery valves to confirm that these were closed. The missing valve handle had not been reported.

The company involved has issued a safety reminder to its personnel as follows:

World-wide, many serious accidents occur due to snaking hoses. It is, therefore, necessary to follow some simple safety precautions efore and during use of any compressor:

  • Before starting up a compressor, ensure that all air delivery valves are shut
  • Check that all valve handles are secured in place
  • Check condition of hose for any physical damage
  • Check all hose line clamps for tightness, to ensure non inadvertent parting of hoses while in use
  • Check all hose connections are secured with safety rope, to prevent a whiplash/snaking effect if parted
  • Ensure insurance wire is fixed on all quick-release couplings to prevent inadvertent parting of couplings while in use
  • Ensure all hose lines are anchored/secured with rope to fixed structures, to prevent a whiplash effect if parted
  • Know where the compressor’s ’emergency stop’ button is situation and how to use it
  • After use, ensure that air-delivery valves are closed and that the delivery hose is coiled and kept safely
  • Report all unsafe acts and unsafe conditions.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.