- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
BSEE: Swing rope transfers
The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 456 relating to the dangers inherent to swing rope transfers. The BSEE notes that “personnel transfers using swing ropes and baskets present a considerable risk for offshore workers.” The use of swing ropes is not permitted in some parts of the world.
This is passed on as of interest to members, while noting clearly that IMCA does not recommend the use of swing ropes. (Section 4.4.4, Guidance on the transfer of personnel to and from offshore vessels and structures).
What happened
A recent example of an injury incurred during a swing rope transfer, is a fractured foot sustained by a worker attempting to use a swing rope to board a satellite platform from a work boat. As the Captain manoeuvered the boat, the worker placed his foot on a bumper tire to position himself for the swing. The worker’s foot slipped between the tyre and the boat when the tyre hit the platform, resulting in injury.
A recent example of an injury incurred during a swing rope transfer, is a fractured foot sustained by a worker attempting to use a swing rope to board a satellite platform from a work boat. As the Captain manoeuvered the boat, the worker placed his foot on a bumper tire to position himself for the swing. The worker’s foot slipped between the tyre and the boat when the tyre hit the platform, resulting in injury.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2023/05/Screenshot-2023-05-16-142213.png)
BSEE notes two further injuries in the last five years:
- An employee lacerated his shin after it struck the rear of a vessel as he was completing a swing;
- An employee fell into the water between a workboat and a platform when he misjudged the distance between the boat’s deck and the top of a swell during a swing rope transfer. As he made his swing, the wave shifted the boat, moving the landing area. When the employee let go of the swing rope, he fell into the water. He was quickly retrieved from the water and did not sustain injuries.
BSEE recommends that:
- All offshore personnel transfers are treated as stand-alone operations;
- Formal risk assessment is conducted before a transfer occurs;
- There is “Stop work authority” for all persons involved.
Because of the inherent risks involved, BSEE also recommends that alternative methods are used where practicable and that there is routine assessment of the training and competence of everyone who has responsibilities for, and is involved with, personnel transfer.
As noted above, IMCA does not recommend the use of swing ropes.
Members should refer to IMCA HSSE 025 Guidance on the transfer of personnel to and from offshore vessels and structures.
Safety Event
Published: 16 May 2023
Download: IMCA SF 12/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.