Abrasion of metal casing
A member has reported a case of serious abrasion on the metal casing of the flame arrester on an oxygen hose. This was discovered during ‘routine’ replacement of the securing Jubilee clips on the oxygen hose flame arresters.
Where the hose had been left coiled on its storage brackets and had been able to swing freely back and forth with the movement of the vessel, it was noticed that this had resulted in the abrasion of the underside of the metal casing of the flame arrester. The resulting wear on the metal was sufficient to reveal the O-ring inside the arrester, as can be seen in the photograph.
This rendered the arrester useless, and it is evident from the photograph that oxygen would now be able to leak freely past this area and into the atmosphere, thereby enriching it and making it more readily combustible should fire or a cause of ignition occur.
It is not uncommon for lengths of oxy/acetylene hose to be stored in ‘out of the way’ places, ready to be uncoiled and used on an occasional basis and, as a consequence of this, defects may only be noticed when the equipment is eventually needed.
Jubilee clips may be considered inappropriate for such hose connections as they can easily corrode and, due to their small size, do not provide an adequate sealing effect. Members are recommended to check all such hoses and arresters for wear and damage: this equipment is sometimes needed in a hurry and should always be in a serviceable condition.
Safety Event
Published: 21 May 2008
Download: IMCA SF 09/08
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.