- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
COBRA bailout system – guidance note
JFD have issued a COBRA guidance note relating to concerns regarding the suitability of the 2L composite cylinders contained within the set. This note highlights to users, those reported concerns and the follow-on investigation that has been undertaken to demonstrate suitability of the composite cylinders for the application in COBRA.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2021/07/Screenshot-2021-07-30-084512.jpg)
What happened
Users have reported blistering and flaking of the lacquer on the cylinder exterior, and premature, excessive corrosion on the exposed aluminium at the cylinder neck, as seen in these images:
![](https://imcaweb.blob.core.windows.net/wp-uploads/2021/07/Screenshot-2021-07-30-084606.jpg)
![](https://imcaweb.blob.core.windows.net/wp-uploads/2021/07/Screenshot-2021-07-30-084645.jpg)
Actions taken
- Blistering and flaking
- JFD has investigated and worked closely with the cylinder manufacturer (Worthington Industries) who have categorically stated that flaking of the lacquer is a known but trivial characteristic of composite cylinders. The typical cause is due to air, which is trapped in the composite matrix during manufacture, being forced out during cylinder charging. It is thought that use in a hyperbaric environment can cause this issue to re-occur due to helium migrating under the lacquer over a period of time and then expanding when the set is removed from the dive system.
- The manufacturer has explicitly stated that the voids are too small to allow any water ingress at diving pressures.
- The manufacturer has also explicitly stated that these cylinders are suitable for the duty experienced by a COBRA set (surface, dry hyperbaric helium environment, diving, reasonably fast decompression out of system).
- Premature, excessive corrosion
- JFD carried out an evaluation of the cylinders in question which were certainly corroded beyond what was acceptable for the time in service and, in fact, subsequently failed inspection at an IDEST facility. JFD has contacted the manufacturer to investigate the possibility of a problem with this particular batch of cylinders. To date, the manufacturer has not responded with any information. Your ongoing understanding and support in this matter is much appreciated.
- Some COBRA sets have been in service for much longer periods without reported feedback of excessive corrosion, with the original cylinders still fitted, and others have had replacement cylinders after varying periods of time.
- JFD advises users to check the external condition of the COBRA cylinders every time the COBRA set is removed from the dive system for maintenance, recharging or any other reason. If the cylinder condition is deemed questionable, a replacement should be fitted and the cylinder inspected by an IDEST facility before re-use.
- Additionally, JFD are currently investigating the possibility of supplying a different brand of composite cylinder which has a stainless steel liner. This should eliminate all corrosion issues.
For further information please contact Graeme Clark (Head of Commercial Products) Email: [email protected] Telephone: + 44 ( 0)7770553198
Safety Event
Published: 30 July 2021
Download: IMCA SF 21/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.