- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Confined space entry incidents – a reminder
A member has reported a number of confined space incidents during a class renewal docking of a vessel, and has brought these to IMCA’s attention as a reminder to raise awareness of the hazards of confined space entry.
These incidents occurred when a vessel was undergoing a class renewal docking. During the docking there were numerous requirements for confined space entry. As a result of procedures and the company safe system of work not being followed, a variety of confined space entry incidents occurred involving third-party subcontractors and included one near miss involving company personnel. Due to the diligence of, and the intervention of, company personnel at the worksite, no-one was injured. None of these cases resulted in harm to personnel.
These brief descriptions are taken from our member’s safety database:
- Void space tank lid entry blocked by flammable locker that was welded to the deck preventing safe access/egress;
- Confined space tank cleaning in progress in engine room. No standby person or entrance roster. Entrants were not wearing harnesses as required;
- Standby man identified contractors cutting valves using acetylene without any means of ventilation in a confined space;
- Steel workers in the engine room were undertaking confined space entry work using personal gas detectors supplied by a third party contractor. On examination it was determined that the gas detectors had not been bump tested prior to use. One of the detectors was reading 21.8% for oxygen;
- Confined space entry attendant noted that hot work was taking place in a space without forced ventilation. Reporting person notified the bridge that he was stopping the job and asking contractors to use the required means of ventilation;
- Access to the confined space without informing a standby person;
- Confined space entry attendant observed a fire watch preparing a carbon dioxide fire extinguisher for the enclosed space;
- Electrical cable and oxygen / acetylene hoses approximately 15 cm from halogen light inside a confined space;
- Persons entering into the confined space without Permit to Work. They entered from another tank;
- Whilst performing tank sentry duties, one person was observed attempting to enter a confined space (a wing tank) without a personal gas detector;
- Third party contractor welder attempted to enter tank without wearing a harness;
- Near miss: confined space entry into fuel tank in breach of company integrated safe system of work -after observing smoke coming from open hatch.
Our member notes the following lessons:
- Care should be taken to ensure procedures are being followed and that all crew members remain situationally aware when potential risks are identified in an ever changing work environment;
- All personnel should remain vigilant with contractors on site during dry dockings and maintenance periods;
- In these cases, through the vigilant observations and intervention of the company vessel crew, the hazards were identified and controlled.
Our member notes:
- Bad planning and losing sight of basic safety procedures can cost lives. Work in confined and enclosed spaces has a greater likelihood of causing fatalities, severe injuries and illness than any other type of work on board a ship or marine installation. More people die or are injured in enclosed spaces than through any other related on-board work activity;
- Establishing set drills and procedures for entry into confined spaces, and the rescue from them, may not be enough to bring about the cultural change in everyday work practice that is needed. It has to be second nature for everyone to stop, think and act safely. This means crew members should be properly trained in the risks, and vessel management should be able to demonstrate due diligence and safety leadership when planning and assigning tasks;
- Confined space entry is an ever present danger in the work of marine contractors and if lessons are not learnt, it can be a ‘silent killer’.
Members may wish to review Guidance on safety in shipyards.
Safety Event
Published: 15 December 2015
Download: IMCA SF 22/15
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.