- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Join the global DP Community at the IMCA DP Conference in Amsterdam. 21 and 22 May. Book now
- Register your interest for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands.
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Corrosion pitting on bailout cylinder
A member has reported that during routine inspection and maintenance of the bailout cylinder, the diving supervisor found corrosion pitting on the cylinder body hidden beneath the harness strap.
The company reminded its personnel that seawater trapped for prolonged periods between the cylinder and strap, coupled with the regular rubbing of the harness strap with the cylinder body could cause corrosion pitting on the cylinder. Also that severe corrosion of the cylinder casing causes weakening of the cylinder which can fail with serious consequences. The bailout cylinder was taken out of service and sent for a full maintenance overhaul. The company reminded its personnel of the requirements to carry out regular inspection of such equipment (see Guidance Note IMCA D 018 – Code of practice for the initial and periodic examination, testing and certification of diving plant and equipment).
Safety Event
Published: 1 July 2002
Download: IMCA SF 05/02
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.