- Registration open for IMCA Lifting & Rigging Seminar 2023
- Registration open for IMCA DP Conference 2023
- Check out our events calendar and meet with us at industry events
- Window for submission of IMCA Contractor Members Safety Statistics is now open
- See IMCA in action
- Last few days to enter IMCA Awards
Crane incident
A member has reported a crane incident on one of its vessels. A crane hook snagged a piece of piping, which was lifted as the hook was raised. The piping subsequently fell, missing two people who were on the deck below. No-one was injured.
Investigation of the event revealed the following:
- The crane had been stowed with the hook resting within the open top of a waste skip;
- The waste skip had not been covered by a net or tarpaulin;
- The crane boom and hook had been raised before the banksman had checked that all was okay and given the crane driver clearance to lift.
The following lessons learnt were noted by the company:
- Crane operations must be properly controlled and managed according to company procedures;
- Crane hook stowage positions should be properly assessed by the worksite management team;
- Crane hook stowage positions should be properly implemented by all crane drivers. It was noted that, on occasion, crane hooks had also been tied off to a handrail and that this practice should cease;
- Waste items in a skip should be more appropriately positioned and, if necessary, the skip covered with a net or tarpaulin.
Safety Event
Published: 21 June 2006
Download: IMCA SF 07/06
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.