Crew member thrown to the quay by unplanned movement of small boat
Transport Malta’s Marine Safety Investigation Unit (MSIU) has produced a report into an accident on a tugboat in harbour, which can be found here.
What happened
The tug Spinola was alongside. The cover on the rescue boat needed required replacement; two crew members from another boat were tasked with the job.
To facilitate the task, one of the crew members stepped on the unprotected outboard side of the rescue boat. At this time, he attempted to slacken the tension on the lifting slings holding the rescue boat. As soon as he operated the yellow handle, the rescue boat swung outboard, struck the crew member, and threw him onto the quay.
As a result of this occurrence he suffered from fractures to his left knee and left wrist, a broken nose and cuts to the face. He underwent surgery and physiotherapy and was over a week in hopsital before discharge.
What went wrong?
Some of the conclusions drawn can be summarised thus:
- The crew members were not entirely familiar with the rescue boat davit operation – the davit’s slewing mechanism was activated accidentally, causing the rescue boat to swing outboard, dragging the crewman along with it;
- A risk assessment was not considered necessary for this task, which was considered trivial or routine;
- The injured person was working on the outboard side, where there were no guard rails fitted, nor was a safety harness or a hard hat worn.
A fuller treatment of the incident can be found here.
Members may wish to refer to:
Safety Event
Published: 20 May 2021
Download: IMCA SF 14/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.