- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Damaged high pressure content gauge hoses on bail-outs
What happened?
During diving activities on two occasions in the same 24-hour period, a diver noticed that there was no pressure left in his bail-out bottle. The decision was taken by the Dive Supervisor to recover the diver from the water, as per standard protocol. After recovery, the bail-out bottle and appliances were checked, and it was found that the high pressure content gauge hose on the bail-out was damaged.
Both hoses were replaced for new hoses.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2019/04/19.jpg)
![](https://imcaweb.blob.core.windows.net/wp-uploads/2019/04/20.jpg)
What went wrong?
The short interval in which these two incidents happened triggered an investigation which revealed the following:
- There were two different types of damage:
- cuts; most likely caused by sharp mussels and stones (illustration above left)
- damage caused by bending and overstressing (illustration above right);
- Both hoses were leak tested and found to be leaking through holes near the ferrule connector;
- Both hoses were fitted with bend restrictors;
- The hoses were maintained and tested in accordance with Code of practice for the initial and periodic examination, testing and certification of diving plant and equipment
- The hoses were subjected to a regular visual inspection before every dive;
- Both hoses were in use for up to 4 years and were regularly used.
What were the causes?
Investigation suggested that one type of HP hose is prone to damage near the ferule connector, caused by bending and stressing, regardless of the use of a bend restrictor present at this location. The damage was not sustained in one single occasion but is believed to have developed over time.
What actions were taken?
There are different types of HP hoses on the market with specific characteristics:
- Hose type 1: fatigue like damage may occur near the ferrule over time. When this damage occurs, it can lead to loss of the bail-out within a dive. In order to reduce the risk of this type of damage occurring, annual replacement may be required, depending on usage.
- Hose type 2: does not show the same fatigue damage development as the construction is more flexible and rugged.
![](https://imcaweb.blob.core.windows.net/wp-uploads/2019/04/21.jpg)
![](https://imcaweb.blob.core.windows.net/wp-uploads/2019/04/22.jpg)
Hose type 1 | Hose type 2 | |
Appearance | Thin, smooth, black, shiny | Thick, black, dull-coloured |
Dimensions | Outside diameter 10.8mm | Outside diameter 12.5mm |
Composition | 3 layers:
Thin layer, plastic-like type (shrink fit) Soft woven middle layer Rigid inner layer, hard plastic-like tube |
3 layers:
Thick outer layer, rubber compound Soft woven middle layer Flexible thick inner layer, rubber compound |
Other findings | Layers can move freely from each other
Outer layer easily cut with knife Stiff, hard to bend, inner layer tends to buckle |
Layers are vulcanized to each other
In general, hard to cut with a knife Easier to bend, smaller bending radius, inner layer does not tend to buckle |
Members may wish to refer to:
Safety Event
Published: 25 April 2019
Download: IMCA SF 08/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.