Diver falls into bell maintenance pit
A member has reported that as part of bell maintenance activities, a diver and dive supervisor removed grating from the bell maintenance access pit and positioned it against the moonpool handrail in the bell handling area. After the grating was removed the dive supervisor proceeded into dive control, at which point the diver moved the grating further and overstepped backward into the pit, falling 1m.
The diver sustained a minor laceration to his lower lip and injuries to his ribs on the left hand side of his body, resulting in a lost work day case for the company.
After investigation, the company has reported the following direct and root causes:
- The direct cause of the injuries was the 1m fall into the maintenance pit;
- The root causes included:
- inadequate design/engineering of the bell maintenance pit, including depth of the pit itself;
- risk assessment tools used did not include key hazards associated with the steps being undertaken as part of the overall maintenance work on the bell, including safe access into/out of and around the maintenance pit.
- Basic safety training modules (specifically risk assessment and manual handling) had not been completed within the first week onboard (as per procedure) and could have acted as a refresher for any training previously done on this, before being involved in risk assessing manual handling activities onboard.
The following corrective and preventative measures have been put in place by the company:
- Review of the existing task based risk assessment (TBRA) and creation of a TBRA specific to bell maintenance, including working in and around the bell maintenance access pit;
- False floor installed into maintenance pit to reduce the depth as required;
- Audit and review of employees onboard to ensure minimum safety training modules and requirements have been completed as per procedure.
More detailed one day risk assessment training courses are to be provided to employees on/offshore, above and beyond the risk assessment module contained in the working safely program.
Key lessons highlighted by the company:
- There was no requirement to move the pit grating further after it was placed against the moonpool handrail, in order to continue with the bell maintenance work;
- The bell maintenance pit did not have to be 1m deep in order to be fit for the purpose for carrying out bell maintenance activities;
- Manual handling and falls into the open pit, were not included in the risk assessment tools used, so may not have been recognised and discussed at the time;
- The definition of ‘hazard’ seemed misunderstood, as ‘damage to equipment’ and ‘injury to personnel’ were noted as hazards in the toolbox talk carried out, prior to the task commencing. Hazard understanding and recognition is a vital part of the risk assessment process and those unrecognised, can in turn be uncontrolled and may increase the risk of accidents;
- The toolbox talk carried out before bell maintenance commenced, had not highlighted the fact that the generic TBRA being used, was out of review date, and not specific to the bell maintenance tasks being undertaken.
Tighter control is needed onboard to ensure minimum safety training requirements are undertaken/ commenced as per company procedures.

Safety Event
Published: 9 February 2010
Download: IMCA SF 01/10
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.