- IP Code: Mandatory Code enters into force on 1 July. Make sure your company is up to speed with the changes.
- Early Bird tickets available for the IMCA Global Summit 2024. 3-4 December, Utrecht, Netherlands. Members can save £400.
- Discover how we are helping Members reduce emissions: Explore the ProjectGHG hub now.
- Now booking. Join the Lifting and Rigging community at our Technical Seminar in Amsterdam. Thursday 12 September 2024
- Now booking. Underwater Ship Husbandry Seminar. 10 October 2024, Singapore.
Dropped load – water
What happened?
Riggers were attempting to lift a pallet of bottled water between decks of a vessel when the load hit an Intermediate Bulk Container (IBC), causing several packets of water bottles to fall from the load. The water bottles were in packs of 6 (weight per pack = 9kg) and fell approx. 11m. This was considered a potential fatality based on the DROPS calculator.
The deck area below the load had been secured and barriered off prior to the lift. There were no injuries.
What went wrong? What were the causes?
- The lift was arguably unnecessary; there were already two pallets of water bottles on the lower deck. Also, alternate means of conducting the lift were not considered;
- The risk assessment/lift plan did not specify a safe method of slinging the load to prevent water from dropping should it collide with vessel structure;
- The risk assessment/lift plan did not identify suitable control measures for the activity of lifting into this deck whilst at sea – there were numerous challenges for lifting operations due to restricted space and visibility, which were not taken into account.
What lessons were learned?
- Review task risk assessments and lift plans for lifting of stores, to ensure hazards, controls, slinging and securing methods are suitable, clear and specific, and with due consideration to the specific controls required to reduce the likely probability of the event reoccurring;
- Review the requirement for and positioning of stores to minimise lifts to be carried out at sea, e.g. sufficient stores loaded alongside or on main deck.
Members may wish to refer to:
Safety Event
Published: 28 May 2019
Download: IMCA SF 12/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.